Ductless Fume Hoods provide a ventilated enclosure that directs methylene chloride fumes away from the operator’s breathing zone.
The US Environmental Protection Agency (EPA) recently restricted the use of methylene chloride and imposed stricter exposure limits for exempt entities (Bermudez 2025). The EPA banned most consumer and industrial uses of methylene chloride but allowed its use for certain exempt purposes (UCSF 2026). For exempt uses, the EPA significantly reduced the exposure limit from the OSHA limit of 25 ppm to 2 ppm (Bermudez 2025). The original compliance deadline of exempt uses was extended by 18 months to allow exempt entities more time to meet the new exposure limits. See the chart below for the updated enforcement dates. Exempt facilities can use engineering controls, such as fume hoods and fume extractors, to help meet the new EPA guidelines by February 8, 2027 (EPA 2025).
Methylene Chloride Compliance Deadlines for Non-Federal Exempt Uses
| Type | Date |
| Initial Monitoring | November 9, 2026 |
| Compliance with Exposure Limits | February 8, 2027 |
| Exposure Control Plan | May 10, 2027 |
What is methylene chloride?

Methylene chloride used to be found in paint strippers and degreasers but currently only used in laboratories after the EPA ban on consumer and most industrial uses.
Methylene Chloride Exposure Side Effects
Exposure to methylene chloride fumes mainly affects the central nervous system, causing dizziness and confusion or even loss of consciousness (Bermudez 2025). Exposure to high concentrations can lead to asphyxiation or suffocation (Bermudez 2025). Long-term exposure to methylene chloride fumes has been shown to increase the risk of cancer and cause organ damage to the liver, heart, and nervous system (UCSF 2026). Contact with methylene chloride can cause skin and eye irritation (UCSF 2026).
EPA’s New Methylene Chloride Regulations
In April 2024, the EPA outlined new methylene chloride regulations using authority granted under the Toxic Substances Control Act (Bermudez 2025). The EPA restricted uses and significantly reduced the exposure limits because methylene chloride posed an “unreasonable risk to human health” (UCSF 2026). Methylene chloride was banned for most consumer and industrial products starting April 28, 2026 (Bermudez 2025). The new EPA exposure limits for methylene chloride have been significantly reduced, requiring the 8-hour average exposure to not exceed 2 ppm, compared to the old OSHA value of 25 ppm. Please see the chart below for the current regulations compared to the old OSHA exposure limits (UCSF 2026).
Methylene Chloride New EPA Exposure Limits and Old OSHA Limits
| Limit Type | EPA (new) | OSHA (old value) |
| 8 hour TWA (total weight average in an 8-hour shift) | 2 ppm | 25 ppm |
| ST limit (short term – 15 mins) | 16 ppm | 125 ppm |
| Action level | 1 ppm | 12.5 ppm |
Compliance for exempt industries was delayed due to the challenges of meeting the original deadline. Please see the chart in the intro for the current compliance deadlines.
Exempt industries include lab research and aerospace/defense. Non-exempt uses and facilities must phase out methylene chloride by finding suitable substitute solvents. According to the Federal Register published by the EPA, exempt facilities may include (EPA 2025 2):
• Testing laboratories
• Research and development in physical, engineering, and life sciences
• Hazardous waste treatment and disposal
• Solid waste combustors and incinerators
• Colleges, universities, and professional schools
Methylene Chloride Workplace Chemical Protection Program
Exempt facilities must control exposure to methylene chloride fumes by following the Workplace Chemical Protection Program processes. First, facilities that use methylene chloride must conduct initial monitoring to measure the current methylene chloride exposure levels. If the facility’s exposure levels are above the action level of 1 ppm, they will need to implement engineering controls such as ventilation and process enclosures/fume hoods (Bermudez 2025). Proper PPE must also be used, including respirators (if needed), chemically resistant gloves, aprons, and/or sleeves (Bermudez 2025). These facilities will create a written Workplace Chemical Protection Program outlining all exposure control practices. The last step is continued monitoring – facilities below the action level will need to recheck levels every 5 years, but facilities above the action level must recheck every 3-6 months (Bermudez 2025).
Methylene Chloride Engineering Controls
At Sentry Air Systems, we offer a variety of methylene chloride fume control solutions, including ductless fume hoods and portable fume extractors. Our fume control systems equipped with activated carbon filters can efficiently remove most methylene chloride fumes from the airflow.
Ductless Fume Hoods

Ductless Fume Hoods provide efficient methylene chloride fume containment and control. (24″ shown)
This engineering control utilizes a powerful fan to draw chemical fumes produced from under the hood into the filtration system before they reach the operator’s breathing zone. High quality activated carbon filters remove most methylene chloride fumes through a process called adsorption. The contaminated air passes through the activated carbon granules and the chemical fumes stick to their large surface area. Once most fumes have been removed from the airflow, the system releases the cleansed air into the surrounding room. Ductless Fume Hoods can house two filters (HEPA and Carbon) for applications that produce both particles and fumes.
Ductless Fume Hoods Benefits
• Available in a variety of sizes suitable for any size workspace – 12”, 18”, 24”, 30”, 40”, 50”, 60”, and 70”
• Quick lead time – most standard hoods are available to ship in only 5 business days
• Reliable and low maintenance – the only maintenance is periodic filter changes, which depend on the filter type and frequency of use.
• Made in the USA
• Custom options available (with extended lead time) – material, dimensions, custom cutouts/lid

Portable Fume Extractors

Portable Fume Extractors capture methylene chloride fumes at the source. (Model 300 shown)
Portable Fume Extractors Benefits
• Available with different airflows depending on the application and chemical volume used. (Note: airflow may vary depending on the filter configuration; max airflow values provided)
— Model 300 (shown above) – up to 350 CFM
— Model 400 – up to 700 CFM
— Model 500 – up to 728 CFM.
• Quick lead time – ships in 5 business days
• Low maintenance and reliable – the only maintenance is filter changes.
• Made in the USA
• Expert support

Free Chemical Assessment
When working with chemical applications, our on-staff chemical engineer provides a free chemical assessment to ensure the best-fit solution for your application. This short process asks about the chemical concentration, the amount or volume, the process, and how often. Contact us today for your free chemical assessment.
Control Methylene Chloride Fumes in your Laboratory using Activated Carbon Filters and Reliable Ductless Fume Hoods or Portable Fume Extractors from Sentry Air.
Related blogs
• Engineering Controls to Reduce Exposure to Newly EPA-Banned Solvents TCE & PCE
• Laboratory Fume Hoods
• Utilizing Specialty-Blended Activated Carbon Filters to Optimize Chemical Fume Adsorption
• Rotary Evaporator Fume Control
References
Bermudez, M. (2025, September 8). New rules on methylene chloride: What safety professionals need to know. Occupational Health & Safety. https://ohsonline.com/articles/2025/09/08/printpub-bermudez.aspx
EPA (2024, November). A Guide to Complying with the 2024 Methylene Chloride Regulation under the Toxic Substances Control Act (TSCA) (RIN 2070-AK70). https://www.epa.gov/system/files/documents/2024-07/mecl-compliance-guide.pdf
EPA. (2025, November 10). EPA Extends Compliance Deadlines for Methylene Chloride Rule, Easing Challenges for Non-Federal Laboratories. https://www.epa.gov/chemicals-under-tsca/epa-extends-compliance-deadlines-methylene-chloride-rule-easing-challenges-non
EPA. (2025, November 11). Methylene Chloride; Regulation Under the Toxic Substances Control Act (TSCA); Compliance Date Extension. Federal Register. https://www.federalregister.gov/documents/2025/11/13/2025-19881/methylene-chloride-regulation-under-the-toxic-substances-control-act-tsca-compliance-date-extension
UCSF (2026). EPA Restrictions for Methylene Chloride/Dichloromethane (DCM). https://ehs.ucsf.edu/epa-restrictions-methylene-chloridedichloromethane-dcm

Made in the USA