{"id":26877,"date":"2014-02-27T16:39:47","date_gmt":"2014-02-27T16:39:47","guid":{"rendered":"http:\/\/sentryair.com\/blog\/?p=26877"},"modified":"2020-07-01T20:58:06","modified_gmt":"2020-07-01T20:58:06","slug":"new-product-announcement-elevated-stand","status":"publish","type":"post","link":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/","title":{"rendered":"Elevated Stand"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-full wp-image-26899\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg\" alt=\"SAS Elevated Stand dimensions\" width=\"218\" height=\"375\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg 218w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims-174x300.jpg 174w\" sizes=\"(max-width: 218px) 100vw, 218px\" \/>A complementary accessory to our fume extractors, the <a href=\"https:\/\/www.sentryair.com\/fume-extractor-stand.htm\">Elevated Stand <\/a>is a one-of-a-kind, high-strength industrial piece of equipment that secures and elevates our fume extractors up and off of the floor.<\/p>\n<p>The stand takes up almost zero floor space and doesn&#8217;t require wall mounting or ceiling suspension; an option previously hard to come by without expensive overhead duct work.<\/p>\n<p>The stand is ideal for applications with over sized machinery that floor filtration units are unable serve, for environments with open-concept work spaces where wall mounting isn&#8217;t feasible, and even small facilities where floor space is limited.<\/p>\n<table border=\"1\" width=\"445\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"445\"><strong>Elevated Stand Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"133\">\n<h6><b>Total Height<\/b><\/h6>\n<\/td>\n<td width=\"312\">\n<h6>91\u201d (7.58\u2019)<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"133\">\n<h6><b>Base Platform<\/b><\/h6>\n<\/td>\n<td width=\"312\">\n<h6>16\u201d W x 22\u201d L x 0.375&#8243; Thickness<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"133\">\n<h6><b>Top Platform<\/b><\/h6>\n<\/td>\n<td width=\"312\">\n<h6>23\u201d W x 19\u201d L x 0.188&#8243; Thickness<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"133\">\n<h6><b>Weight \u2013 Stand Only<\/b><\/h6>\n<\/td>\n<td width=\"312\">\n<h6>Approx. 133 lbs.<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"133\">\n<h6><b>Stand Material<\/b><\/h6>\n<\/td>\n<td width=\"312\">\n<h6>Carbon Steel with black powder coating<\/h6>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>A few examples of how the Elevated Stand can be configured<\/strong><\/p>\n<div id=\"attachment_26900\" style=\"width: 1290px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/SS-400-MIST-on-stand.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-26900\" class=\" wp-image-26900\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/SS-400-MIST-on-stand.jpg\" alt=\"SAS Elevated Stand with M400 MIST\" width=\"1280\" height=\"720\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/SS-400-MIST-on-stand.jpg 1280w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/SS-400-MIST-on-stand-300x168.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/SS-400-MIST-on-stand-1024x576.jpg 1024w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/SS-400-MIST-on-stand-500x281.jpg 500w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><\/a><p id=\"caption-attachment-26900\" class=\"wp-caption-text\">CNC Machines are an expensive investment. Instead of cutting large mounting holes into the machine for a coolant\/oil mist collector, mount the collector to our stand and connect our Black Flex Sentry arm to the machine&#8217;s existing portal.<\/p><\/div>\n<div id=\"attachment_26901\" style=\"width: 151px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/ss-400-ms-fes.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-26901\" class=\" wp-image-26901 \" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/ss-400-ms-fes.jpg\" alt=\"If your application requires an elevated fume extraction system but there is limited wall space, or you are unable to mount to a wall, simply mount our fume extractor with Sky Sentry arm to the stand to attain the desired elevation.\" width=\"141\" height=\"378\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/ss-400-ms-fes.jpg 815w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/ss-400-ms-fes-381x1024.jpg 381w\" sizes=\"(max-width: 141px) 100vw, 141px\" \/><\/a><p id=\"caption-attachment-26901\" class=\"wp-caption-text\">If your application requires an elevated fume extraction system but there is limited wall space, or you are unable to mount to a wall, simply mount our fume extractor with Sky Sentry arm to <a href=\"https:\/\/www.sentryair.com\/fume-extractor-stand.htm\">the stand<\/a> to attain the desired elevation.<\/p><\/div>\n<div id=\"attachment_26903\" style=\"width: 243px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/Stand-with-700.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-26903\" class=\" wp-image-26903 \" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/Stand-with-700.jpg\" alt=\"For ambient room air cleaning, mount either our Model 700 (pictured) or Model 2000 air cleaners to the stand to create the optimal airflow pattern in your facility. \" width=\"233\" height=\"415\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/Stand-with-700.jpg 1080w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/Stand-with-700-168x300.jpg 168w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/Stand-with-700-576x1024.jpg 576w\" sizes=\"(max-width: 233px) 100vw, 233px\" \/><\/a><p id=\"caption-attachment-26903\" class=\"wp-caption-text\">For ambient room air cleaning, mount either our Model 700 (pictured) or Model 2000 air cleaners to <a href=\"https:\/\/www.sentryair.com\/fume-extractor-stand.htm\">the stand<\/a> to create the optimal airflow pattern in your facility.<\/p><\/div>\n<div id=\"attachment_26904\" style=\"width: 978px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/DSC_4606_reduced.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-26904\" class=\"size-full wp-image-26904\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/DSC_4606_reduced.jpg\" alt=\"If your facility has open-concept stations or has workbenches in the middle of a room, avoid a costly ceiling exhaust system by mounting one of our fume extractors to the stand with our 7' or 10' Hybrid Arm for extended reach, rotation and flexibility.\" width=\"968\" height=\"648\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/DSC_4606_reduced.jpg 968w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/DSC_4606_reduced-300x200.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/DSC_4606_reduced-448x300.jpg 448w\" sizes=\"(max-width: 968px) 100vw, 968px\" \/><\/a><p id=\"caption-attachment-26904\" class=\"wp-caption-text\">If your facility has open-concept stations or has workbenches in the middle of a room, avoid a costly ceiling exhaust system by mounting one of our fume extractors to the stand with our 7&#8242; or 10&#8242; Hybrid Arm for extended reach, rotation and flexibility.<\/p><\/div>\n<p><strong>Stand compatibilities<i><\/i><\/strong><\/p>\n<p>Sentry Air Systems fume extractors are known for their modular design, making them highly interchangeable for a variety of applications.<\/p>\n<p>When creating the <a href=\"https:\/\/www.sentryair.com\/fume-extractor-stand.htm\">Elevated Stan<\/a>d, a similar design philosophy was used. The result is a highly compact, industrial-strength product that works with a variety of units and exhaust arms.<\/p>\n<div align=\"center\">\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"5\" width=\"503\"><strong>Elevated Stand Compatibility with Sentry Air units<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"79\"><b>Series 300<\/b><\/td>\n<td width=\"84\"><b>Series 400<\/b><\/td>\n<td width=\"85\"><b>Series 450<\/b><\/td>\n<td width=\"144\"><b>Ambient Air Cleaners<\/b><\/td>\n<td width=\"111\"><b>Exhaust Arms<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"79\">\n<h6>SS-300-MS<\/h6>\n<h6>SS-300-MSP<\/h6>\n<h6>SS-300-SKY<\/h6>\n<h6>SS-300-MIST<\/h6>\n<\/td>\n<td valign=\"top\" width=\"84\">\n<h6>SS-400-MS<\/h6>\n<h6>SS-400-MSP<\/h6>\n<h6>SS-400-SKY<\/h6>\n<h6>SS-400-MIST<\/h6>\n<\/td>\n<td valign=\"top\" width=\"85\">\n<h6>SS-450-MS<\/h6>\n<h6>SS-450-MSP<\/h6>\n<h6>SS-450-SKY<\/h6>\n<h6>SS-450-MIST<\/h6>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<h6>SS-700-FH<\/h6>\n<h6>SS-2000-FH<\/h6>\n<\/td>\n<td valign=\"top\" width=\"111\">\n<h6>Black Flex Sentry<\/h6>\n<h6>Hybrid Arm<\/h6>\n<h6>Python Arm<\/h6>\n<h6>Sky Arm<\/h6>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\"><strong>Tested for strength and stability<\/strong><\/p>\n<p style=\"text-align: left;\">All our products undergo stringent quality testing for safety and longevity. For the Elevated Stand, we spared no expense and used a third party engineering firm to conduct multiple structural tests including weight loads and bend radii to determine max operating levels. The results were favorable and reaffirmed the stand&#8217;s quality and safety.<\/p>\n<p style=\"text-align: left;\"><strong>Why Facility Managers and their wallets will enjoy the stand<\/strong><\/p>\n<p style=\"text-align: left;\">The <a href=\"https:\/\/www.sentryair.com\/fume-extractor-stand.htm\">Elevated Stand<\/a> eliminates the headache of having to locate wall or ceiling space suitable for mounting heavy units. This is especially helpful if you work in a facility with strict codes or installation requirements. The only necessary install is securing the stand to a suitable floor.<\/p>\n<p style=\"text-align: left;\">Also, by mounting our fume extractor and hose to the stand, you are saving thousands in costly overhead duct work and you can easily take your entire fume extraction system with you if your business ever moves to a new location or building.<\/p>\n<p style=\"text-align: left;\"><b><\/b><strong>Contact Sentry Air<\/strong><\/p>\n<p style=\"text-align: left;\">For more information about our Elevated Stand or to receive a free quote, contact <b>Sentry Air Systems<\/b> at 800.799.4609, email <a href=\"mailto:sales@sentryair.com\">sales@sentryair.com<\/a>, visit our <a href=\"https:\/\/www.sentryair.com\/\">website<\/a> or fill out the feedback form below.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A complementary accessory to our fume extractors, the Elevated Stand is a one-of-a-kind, high-strength industrial piece of equipment that secures and elevates our fume extractors up and off of the floor. The stand takes up almost zero floor space and doesn&#8217;t require wall mounting or ceiling suspension; an option previously hard to come by without&#8230;  <a class=\"excerpt-read-more btn btn-primary\" style=\"display:block; color: #fff;  margin-top: 10px; max-width:120px;\" href=\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/\" title=\"Read Elevated Stand\">Learn More<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[2773,1091],"tags":[],"class_list":["post-26877","post","type-post","status-publish","format-standard","hentry","category-fume-extractors","category-product-accessories"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Elevated Stand - Sentry Air Systems, Inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Elevated Stand - Sentry Air Systems, Inc.\" \/>\n<meta property=\"og:description\" content=\"A complementary accessory to our fume extractors, the Elevated Stand is a one-of-a-kind, high-strength industrial piece of equipment that secures and elevates our fume extractors up and off of the floor. The stand takes up almost zero floor space and doesn&#8217;t require wall mounting or ceiling suspension; an option previously hard to come by without... Learn More\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/\" \/>\n<meta property=\"og:site_name\" content=\"Sentry Air Systems, Inc.\" \/>\n<meta property=\"article:published_time\" content=\"2014-02-27T16:39:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-01T20:58:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg\" \/>\n<meta name=\"author\" content=\"sentryair\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sentryair\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/\",\"url\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/\",\"name\":\"Elevated Stand - Sentry Air Systems, Inc.\",\"isPartOf\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg\",\"datePublished\":\"2014-02-27T16:39:47+00:00\",\"dateModified\":\"2020-07-01T20:58:06+00:00\",\"author\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#primaryimage\",\"url\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg\",\"contentUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg\",\"width\":218,\"height\":375},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sentryair.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Elevated Stand\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\",\"url\":\"https:\/\/www.sentryair.com\/blog\/\",\"name\":\"Sentry Air Systems, Inc.\",\"description\":\"Air Purification Systems, Ductless Hoods &amp; Fume Extractors\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\",\"name\":\"sentryair\",\"sameAs\":[\"http:\/\/www.sentryair.com\"],\"url\":\"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Elevated Stand - Sentry Air Systems, Inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/","og_locale":"en_US","og_type":"article","og_title":"Elevated Stand - Sentry Air Systems, Inc.","og_description":"A complementary accessory to our fume extractors, the Elevated Stand is a one-of-a-kind, high-strength industrial piece of equipment that secures and elevates our fume extractors up and off of the floor. The stand takes up almost zero floor space and doesn&#8217;t require wall mounting or ceiling suspension; an option previously hard to come by without... Learn More","og_url":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/","og_site_name":"Sentry Air Systems, Inc.","article_published_time":"2014-02-27T16:39:47+00:00","article_modified_time":"2020-07-01T20:58:06+00:00","og_image":[{"url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg"}],"author":"sentryair","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sentryair","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/","url":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/","name":"Elevated Stand - Sentry Air Systems, Inc.","isPartOf":{"@id":"https:\/\/www.sentryair.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#primaryimage"},"image":{"@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg","datePublished":"2014-02-27T16:39:47+00:00","dateModified":"2020-07-01T20:58:06+00:00","author":{"@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5"},"breadcrumb":{"@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#primaryimage","url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg","contentUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2014\/02\/stand-dims.jpg","width":218,"height":375},{"@type":"BreadcrumbList","@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-extractors\/new-product-announcement-elevated-stand\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sentryair.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Elevated Stand"}]},{"@type":"WebSite","@id":"https:\/\/www.sentryair.com\/blog\/#website","url":"https:\/\/www.sentryair.com\/blog\/","name":"Sentry Air Systems, Inc.","description":"Air Purification Systems, Ductless Hoods &amp; Fume Extractors","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5","name":"sentryair","sameAs":["http:\/\/www.sentryair.com"],"url":"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/26877"}],"collection":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/comments?post=26877"}],"version-history":[{"count":5,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/26877\/revisions"}],"predecessor-version":[{"id":336077,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/26877\/revisions\/336077"}],"wp:attachment":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/media?parent=26877"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/categories?post=26877"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/tags?post=26877"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}