{"id":334224,"date":"2018-08-06T17:59:32","date_gmt":"2018-08-06T17:59:32","guid":{"rendered":"https:\/\/www.sentryair.com\/blog\/?p=334224"},"modified":"2023-07-25T18:18:10","modified_gmt":"2023-07-25T18:18:10","slug":"what-is-a-ductless-fume-hood","status":"publish","type":"post","link":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/","title":{"rendered":"What is a Ductless Fume Hood?"},"content":{"rendered":"<h2>A ductless fume hood is a <strong>contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away<\/strong> from the <em>operator\u2019s respiratory zone<\/em> and protects the <em>operator and the environment<\/em> from exposure.<\/h2>\n<p>&nbsp;<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<div style=\"background-color:#002A92;color:white;padding:5px;\">\n<h2><center><font color=\"#FFFFFF\">How does a Ductless Fume Hood work?<\/font><\/center><\/h2>\n<\/div>\n<p>&nbsp;<br \/>\n<a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2.jpg\"><img decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg\" alt=\"Ductless Fume Hood Diagram\" class=\"aligncenter\"><\/a><br \/>\n&nbsp;<\/p>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-02-Number1.jpg\" alt=\"Ductless Fume Hood\" width=\"140\" height=\"124\" class=\"alignleft size-full wp-image-334248\"><\/div>\n<div style=\"width:90%;padding:0 10px 0 0;float:left;\">\nAmbient Air is drawn into the hood and mixed with fumes, vapors or particulates emitted from the process.<\/div>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-03-Number2.jpg\" alt=\"Ductless Fume Hood\" width=\"140\" height=\"124\" class=\"alignleft size-full wp-image-334252\"><\/div>\n<div style=\"width:90%;padding:0 10px 0 0;float:left;\">\nThe air within the hood is processed through a pre-filter where some particles are captured.<\/div>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-04-Number3.jpg\" alt=\"Ductless Fume Hood\" width=\"140\" height=\"124\" class=\"alignleft size-full wp-image-334256\"><\/div>\n<div style=\"width:90%;padding:0 10px 0 0;float:left;\">\nAir is filtered through the main filter (HEPA, ULPA, ASHRAE, Activated Carbon or Specialty Blended).<\/div>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-05-Number4.jpg\" alt=\"Ductless Fume Hood\" width=\"140\" height=\"124\" class=\"alignleft size-full wp-image-334257\"><\/div>\n<div style=\"width:90%;padding:0 10px 0 0;float:left;\">\nFiltered air is released back into the room eliminating the need for duct work.<\/div>\n<\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:right;\">\n<div style=\"background-color:#002A92;color:white;padding:5px;\">\n<h2><center><font color=\"#FFFFFF\">Anatomy of a Ductless Fume Hood<\/font><\/center><\/h2>\n<\/div>\n<p>&nbsp;<br \/>\n<a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-06-SideDiagram.jpg\"><img decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-06-SideDiagram-sm.jpg\" alt=\"Ductless Fume Hood Diagram\" class=\"aligncenter\"><\/a><\/p>\n<div style=\"background-color:#002A92;color:white;padding:5px;\">\n<h2><center><font color=\"#FFFFFF\">Advantages of a Ductless Fume Hood<\/font><\/center><\/h2>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>Portable<\/h3>\n<\/div>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>Long Filter Life<\/h3>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>Quiet Operation<\/h3>\n<\/div>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>Sturdy Construction<\/h3>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>Low Maintenance<\/h3>\n<\/div>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>Simple Filter Change<\/h3>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>Variety of Sizes<\/h3>\n<\/div>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>No Ductwork<\/h3>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:10%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-07-Checkmark.jpg\" alt=\"\" width=\"192\" height=\"156\" class=\"alignleft size-full wp-image-334265\"><\/div>\n<div style=\"width:40%;padding:0 10px 0 0;float:left;\">\n<h3>No Makeup Air<\/h3>\n<\/div>\n<\/div>\n<div style=\"clear:both;\"><\/div>\n<div style=\"background-color:#002A92;color:white;padding:5px;\">\n<h2><center><font color=\"#FFFFFF\">Ductless Fume Hood Main Filter Choices<\/font><\/center><\/h2>\n<\/div>\n<div style=\"background-color:gray;color:white;padding:0px;\">\n<h4><strong><center><font color=\"#FFFFFF\">PARTICULATE FILTERS<\/font><\/center><\/strong><\/h4>\n<\/div>\n<div style=\"width:33%;padding:0 10px 0 0;float:left;\">\n<h2><strong>ULPA Filter<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-08-ULPAefficiency-300x276.jpg\" alt=\"Ductless Fume Hood - ULPA filter efficiency\" width=\"300\" height=\"276\" class=\"alignleft size-medium wp-image-334291\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-08-ULPAefficiency-300x276.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-08-ULPAefficiency.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h4>up to<br \/>\n99.9995%<br \/>\nEfficiency<\/h4>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-09-ULPAparticle-300x154.jpg\" alt=\"Ductless Fume Hood ULPA particle\" width=\"300\" height=\"154\" class=\"alignleft size-medium wp-image-334298\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-09-ULPAparticle-300x154.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-09-ULPAparticle.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h4>down to<br \/>\n0.12 microns<\/h4>\n<\/div>\n<\/div>\n<div style=\"width:33%;padding:0 10px 0 0;float:left;\">\n<h2><strong>HEPA Filter<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-10-HEPAefficiency-300x276.jpg\" alt=\"Ductless Fume Hood - HEPA filter efficiency\" width=\"300\" height=\"276\" class=\"alignleft size-medium wp-image-334296\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-10-HEPAefficiency-300x276.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-10-HEPAefficiency.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h4>up to<br \/>\n99.97%<br \/>\nEfficiency<\/h4>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-11-HEPAparticle-300x154.jpg\" alt=\"\" width=\"300\" height=\"154\" class=\"alignleft size-medium wp-image-334302\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-11-HEPAparticle-300x154.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-11-HEPAparticle.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h4>down to<br \/>\n0.3 microns<\/h4>\n<\/div>\n<\/div>\n<div style=\"width:33%;padding:0 10px 0 0;float:left;\">\n<h2><strong>ASHRAE Filter<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-12-ASHRAEefficiency-300x275.jpg\" alt=\"Ductless Fume Hood ASHRAE efficiency\" width=\"300\" height=\"275\" class=\"alignleft size-medium wp-image-334303\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-12-ASHRAEefficiency-300x275.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-12-ASHRAEefficiency.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h4>up to<br \/>\n95%<br \/>\nEfficiency<\/h4>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-13-ASHRAEparticle-300x154.jpg\" alt=\"Ductless Fume Hood ASHRAE particle\" width=\"300\" height=\"154\" class=\"alignleft size-medium wp-image-334304\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-13-ASHRAEparticle-300x154.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-13-ASHRAEparticle.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h4>down to<br \/>\n0.5 microns<\/h4>\n<\/div>\n<\/div>\n<div style=\"clear:both;\"><\/div>\n<p>&nbsp;<\/p>\n<div style=\"background-color:black;color:white;padding:0px;\">\n<h4><strong><center><font color=\"#FFFFFF\">CHEMICAL FILTERS<\/font><\/center><\/strong><\/h4>\n<\/div>\n<div style=\"width:33%;padding:0 10px 0 0;float:left;\">\n<h2><strong>Activated Carbon<\/strong><\/h2>\n<div style=\"width:40%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-14-ActivatedCarbon-183x300.jpg\" alt=\"\" width=\"183\" height=\"300\" class=\"alignleft size-medium wp-image-334310\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-14-ActivatedCarbon-183x300.jpg 183w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-14-ActivatedCarbon.jpg 404w\" sizes=\"(max-width: 183px) 100vw, 183px\" \/><\/div>\n<div style=\"width:60%;padding:0 5px 0 0;float:left;\">\nTreated Carbon that has increased surface area in order to be more porous to adsorb chemical fumes.<\/div>\n<p>&nbsp;<\/p>\n<h4>Efficiency depends on chemical<\/h4>\n<\/div>\n<div style=\"width:66%;padding:0 10px 0 0;float:left;\">\n<h2><strong>Specialty Blended<\/strong><\/h2>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-15-AcidGas-300x286.jpg\" alt=\"Acid Gas - Ductless Fume Hood\" width=\"300\" height=\"286\" class=\"alignleft size-medium wp-image-334317\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-15-AcidGas-300x286.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-15-AcidGas.jpg 319w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Acid Gas<\/h4>\n<\/div>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-17-Aldehyde-300x286.jpg\" alt=\"Aldehyde - Ductless Fume Hood\" width=\"300\" height=\"286\" class=\"alignleft size-medium wp-image-334319\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-17-Aldehyde-300x286.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-17-Aldehyde.jpg 319w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Aldehyde<\/h4>\n<\/div>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-18-Ammonia-300x286.jpg\" alt=\"Ammonia - Ductless Fume Hood\" width=\"300\" height=\"286\" class=\"alignleft size-medium wp-image-334323\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-18-Ammonia-300x286.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-18-Ammonia.jpg 319w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Ammonia<\/h4>\n<\/div>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-16-Mercury-300x286.jpg\" alt=\"Mercury - Ductless Fume Hood\" width=\"300\" height=\"286\" class=\"alignleft size-medium wp-image-334324\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-16-Mercury-300x286.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-16-Mercury.jpg 319w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:25%;padding:0 10px 0 0;float:left;\">\n<h4>Mercury<\/h4>\n<\/div>\n<\/div>\n<div style=\"clear:both;\"><\/div>\n<p>&nbsp;<\/p>\n<div style=\"background-color:#002A92;color:white;padding:10px;\">\n<h2><center><font color=\"#FFFFFF\">Ductless Fume Hood Uses<\/font><\/center><\/h2>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-19-3DPrinting-300x278.jpg\" alt=\"Ductless Fume Hood - 3D Printing\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334332\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-19-3DPrinting-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-19-3DPrinting.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>3D Printing<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-20-Archaeology-300x278.jpg\" alt=\"Ductless Fume Hood Archaeology\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334333\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-20-Archaeology-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-20-Archaeology.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Archaeology<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-21-ChemicalFumes-300x278.jpg\" alt=\"Ductless Fume Hood Chemical Fumes\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334337\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-21-ChemicalFumes-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-21-ChemicalFumes.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Chemical Fumes<\/h4>\n<\/div>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-22-DNA-300x278.jpg\" alt=\"Ductless Fume Hood DNA\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334339\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-22-DNA-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-22-DNA.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>DNA<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-23-Forensic-300x278.jpg\" alt=\"Ductless Fume Hood Forensic\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334340\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-23-Forensic-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-23-Forensic.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Forensic<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-24-GlassesManufacturing-300x278.jpg\" alt=\"Ductless Fume Hood Glasses Manufacturing\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334341\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-24-GlassesManufacturing-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-24-GlassesManufacturing.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Glasses Manufacturing<\/h4>\n<\/div>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-25-Mycology-300x278.jpg\" alt=\"Ductless Fume Hood Mycology\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334342\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-25-Mycology-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-25-Mycology.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Mycology<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-26-PaintsGluesSolvents-300x278.jpg\" alt=\"Ductless Fume Hood Paints Glues Solvents\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334343\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-26-PaintsGluesSolvents-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-26-PaintsGluesSolvents.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Paints, Glues, Solvents<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-27-Pharmaceutical-300x278.jpg\" alt=\"Ductless Fume Hood Pharmaceutical\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334344\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-27-Pharmaceutical-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-27-Pharmaceutical.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Pharmaceutical<\/h4>\n<\/div>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-28-artrestoration-300x278.jpg\" alt=\"Ductless Fume Hood Restoration of Art\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334345\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-28-artrestoration-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-28-artrestoration.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Restoration of Art<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-29-Soldering-300x278.jpg\" alt=\"Ductless Fume Hood Soldering\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334346\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-29-Soldering-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-29-Soldering.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Soldering<\/h4>\n<\/div>\n<div style=\"width:17%;padding:0 5px 0 0;float:left;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-30-stemcells-300x278.jpg\" alt=\"Ductless Fume Hood Stem Cells\" width=\"300\" height=\"278\" class=\"alignleft size-medium wp-image-334347\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-30-stemcells-300x278.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-30-stemcells.jpg 428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n<div style=\"width:16%;padding:0 5px 0 0;float:left;\">\n&nbsp;<\/p>\n<h4>Stem Cells<\/h4>\n<\/div>\n<div style=\"clear: both;\"><\/div>\n<h4>Other Biological Applications or Processes Requiring Dust Removal<\/h4>\n<div style=\"background-color:#002A92;color:white;padding:10px;\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/SAS_white-transparent-300x111.png\" alt=\"Sentry Air Systems - white logo\" width=\"300\" height=\"111\" class=\"alignleft size-medium wp-image-334354\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/SAS_white-transparent-300x111.png 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/SAS_white-transparent-768x284.png 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/SAS_white-transparent-1024x378.png 1024w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h4><em><font color=\"#FFFFFF\">Simple Solutions for Cleaner Air<\/font><\/em><\/h4>\n<p><font color=\"#FFFFFF\">1.800.799.4609<\/font> \u2022 <a href=\"mailto:sales@sentryair.com\">sales@sentryair.com<\/a><br \/>\n<a href=\"https:\/\/www.sentryair.com\/?utm_source=Blog%2C%20Ductless%20Fume%20Hood%20Infographic&amp;utm_medium=blog&amp;utm_campaign=Ductless_Fume_Hood_Infographic\" target=\"_blank\" rel=\"noopener\">www.sentryair.com<\/a><\/p>\n<\/div>\n<p>&nbsp;<br \/>\n&nbsp;<br \/>\n&nbsp;<br \/>\n&nbsp;<br \/>\n<center><\/p>\n<form>\n<input style=\"width: 500px; padding: 20px; cursor: pointer; box-shadow: 6px 6px 5px; #999; -webkit-box-shadow: 6px 6px 5px #999; -moz-box-shadow: 6px 6px 5px #999; font-weight: bold; background: gray; color: white; border-radius: 10px; border: 1px solid #999; font-size: 150%;\" type=\"button\" value=\"Download Infographic as an Image\" onclick=\"window.location.href='http:\/\/bit.ly\/2vmovOx'\"><br \/>\n<\/form>\n<p><\/center><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A ductless fume hood is a contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away from the operator\u2019s respiratory zone and protects the operator and the environment from exposure. &nbsp; How does a Ductless Fume Hood work? &nbsp; &nbsp; Ambient Air is drawn into the hood and mixed&#8230;  <a class=\"excerpt-read-more btn btn-primary\" style=\"display:block; color: #fff;  margin-top: 10px; max-width:120px;\" href=\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/\" title=\"Read What is a Ductless Fume Hood?\">Learn More<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[84],"tags":[],"class_list":["post-334224","post","type-post","status-publish","format-standard","hentry","category-ductless-fume-hood"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What is a Ductless Fume Hood? | Fume Extractor Hood | Sentry Air Systems<\/title>\n<meta name=\"description\" content=\"A ductless fume hood is a contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is a Ductless Fume Hood? | Fume Extractor Hood | Sentry Air Systems\" \/>\n<meta property=\"og:description\" content=\"A ductless fume hood is a contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/\" \/>\n<meta property=\"og:site_name\" content=\"Sentry Air Systems, Inc.\" \/>\n<meta property=\"article:published_time\" content=\"2018-08-06T17:59:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-25T18:18:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg\" \/>\n<meta name=\"author\" content=\"sentryair\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sentryair\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/\",\"url\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/\",\"name\":\"What is a Ductless Fume Hood? | Fume Extractor Hood | Sentry Air Systems\",\"isPartOf\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg\",\"datePublished\":\"2018-08-06T17:59:32+00:00\",\"dateModified\":\"2023-07-25T18:18:10+00:00\",\"author\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\"},\"description\":\"A ductless fume hood is a contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#primaryimage\",\"url\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg\",\"contentUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg\",\"width\":331,\"height\":457},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sentryair.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is a Ductless Fume Hood?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\",\"url\":\"https:\/\/www.sentryair.com\/blog\/\",\"name\":\"Sentry Air Systems, Inc.\",\"description\":\"Air Purification Systems, Ductless Hoods &amp; Fume Extractors\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\",\"name\":\"sentryair\",\"sameAs\":[\"http:\/\/www.sentryair.com\"],\"url\":\"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is a Ductless Fume Hood? | Fume Extractor Hood | Sentry Air Systems","description":"A ductless fume hood is a contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/","og_locale":"en_US","og_type":"article","og_title":"What is a Ductless Fume Hood? | Fume Extractor Hood | Sentry Air Systems","og_description":"A ductless fume hood is a contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away","og_url":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/","og_site_name":"Sentry Air Systems, Inc.","article_published_time":"2018-08-06T17:59:32+00:00","article_modified_time":"2023-07-25T18:18:10+00:00","og_image":[{"url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg"}],"author":"sentryair","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sentryair","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/","url":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/","name":"What is a Ductless Fume Hood? | Fume Extractor Hood | Sentry Air Systems","isPartOf":{"@id":"https:\/\/www.sentryair.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#primaryimage"},"image":{"@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg","datePublished":"2018-08-06T17:59:32+00:00","dateModified":"2023-07-25T18:18:10+00:00","author":{"@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5"},"description":"A ductless fume hood is a contained working space that uses powerful negative airflow to pull harmful fumes, vapors or particulate away","breadcrumb":{"@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#primaryimage","url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg","contentUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/08\/DuctlessFumeHoodInfographic-01-Diagram2-sm.jpg","width":331,"height":457},{"@type":"BreadcrumbList","@id":"https:\/\/www.sentryair.com\/blog\/product-review\/fume-hoods\/ductless-fume-hood\/what-is-a-ductless-fume-hood\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sentryair.com\/blog\/"},{"@type":"ListItem","position":2,"name":"What is a Ductless Fume Hood?"}]},{"@type":"WebSite","@id":"https:\/\/www.sentryair.com\/blog\/#website","url":"https:\/\/www.sentryair.com\/blog\/","name":"Sentry Air Systems, Inc.","description":"Air Purification Systems, Ductless Hoods &amp; Fume Extractors","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5","name":"sentryair","sameAs":["http:\/\/www.sentryair.com"],"url":"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334224"}],"collection":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/comments?post=334224"}],"version-history":[{"count":119,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334224\/revisions"}],"predecessor-version":[{"id":338084,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334224\/revisions\/338084"}],"wp:attachment":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/media?parent=334224"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/categories?post=334224"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/tags?post=334224"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}