{"id":334722,"date":"2018-10-24T21:27:10","date_gmt":"2018-10-24T21:27:10","guid":{"rendered":"https:\/\/www.sentryair.com\/blog\/?p=334722"},"modified":"2021-02-10T19:14:56","modified_gmt":"2021-02-10T19:14:56","slug":"iv-bag-preparation","status":"publish","type":"post","link":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/","title":{"rendered":"IV Bag Preparation Best Practices Utilizing ISO Class 5 Laminar Flow Hoods"},"content":{"rendered":"<p><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3-1024x666.jpg\" alt=\"IV Bag Preparation\" width=\"680\" height=\"442\" class=\"aligncenter size-large wp-image-335074\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3-1024x666.jpg 1024w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3-300x195.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3-768x500.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg 1500w\" sizes=\"(max-width: 680px) 100vw, 680px\" \/><\/a><br \/>\nMedical professionals and naturopathic\/holistic doctors have utilized IV vitamin\/nutrient therapies for many years as a more natural approach to treating chronic conditions in patients. As opposed to oral medications or supplements that travel through the body\u2019s digestive system, whereby diminishing absorption capabilities, IV therapy delivers optimal levels of the necessary vitamins\/supplements directly to the bloodstream; often resulting in immediate therapeutic responses<a href=\"#Source1\"><sup>1<\/sup><\/a>.<\/p>\n<p>In addition to an overall increase in energy levels, IV vitamin\/nutrient infusions have been found to help patients with a variety of medical conditions such as<a href=\"#Source2\"><sup>2<\/sup><\/a>:<\/p>\n<table>\n<tbody>\n<tr>\n<td>Alzheimer\u2019s Dementia<\/td>\n<td>Amyotrophic Lateral Sclerosis<\/td>\n<td>Anxiety<\/td>\n<\/tr>\n<tr>\n<td>Asthma (Acute &amp; Chronic)<\/td>\n<td>Arthritis<\/td>\n<td>Autoimmune Illness<\/td>\n<\/tr>\n<tr>\n<td>Cancer<\/td>\n<td>Celiac Disease<\/td>\n<td>Chronic Fatigue Syndrome<\/td>\n<\/tr>\n<tr>\n<td>Constipation<\/td>\n<td>Depression<\/td>\n<td>Diabetes Mellitus<\/td>\n<\/tr>\n<tr>\n<td>Eczema<\/td>\n<td>Headaches<\/td>\n<td>Hypertension<\/td>\n<\/tr>\n<tr>\n<td>Immune Disorders<\/td>\n<td>Macular Degeneration<\/td>\n<td>Multiple Sclerosis<\/td>\n<\/tr>\n<tr>\n<td>Neuropathy<\/td>\n<td>Parkinson\u2019s Disease<\/td>\n<td>Scleroderma<\/td>\n<\/tr>\n<tr>\n<td>Shingles<\/td>\n<td>Toxicity Syndrome<\/td>\n<td>Vitiligo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Vitamin Infusion IV Bag Preparation and Best Practices<\/h2>\n<p><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV2.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV2-300x230.jpg\" alt=\"IV Bag Preparation\" width=\"300\" height=\"230\" class=\"alignleft size-medium wp-image-335075\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV2-300x230.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV2-768x589.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV2-1024x785.jpg 1024w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV2.jpg 1101w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv7.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv7-204x300.jpg\" alt=\"\" width=\"300\" height=\"441\" class=\"alignleft size-medium wp-image-335190\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv7-204x300.jpg 204w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv7-768x1131.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv7-696x1024.jpg 696w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv7.jpg 1019w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>Currently, the FDA does not explicitly regulate the process for IV bag preparation and filling for the use of vitamin\/nutrient infusion therapy. However in recent years, the FDA has deferred to a US Pharmacopeia document entitled <strong>\u201cUSP 797: Pharmaceutical Compounding \u2013 Sterile Preparations\u201d<\/strong> for possible future guidelines and regulations.<\/p>\n<p>In her online publication entitled \u201cBest Practices Guidelines for IV Preparation\u201d, Colleen Huber, NMD, thoroughly explains how the USP 797 document allows a variance in sterile compounding risk levels and how healthcare professionals are allowed to use medical judgment regarding best practices to ultimately ensure a safe product for the patient<a href=\"#Source3\"><sup>3<\/sup><\/a>.<\/p>\n<p>Ms. Huber\u2019s manual on best practices for IV bag preparation includes standard aseptic techniques to prevent cross-contamination. In the section entitled \u201cCompounding Conditions \u2013 The IV Preparation Room\u201d, Ms. Huber recommends that \u201cthe room in which compounded sterile products containing IV nutrients are prepared, should rise to the following standards: to be adequately lit,<strong> <em>with ventilation, air filters replaced once every two months,<\/em><\/strong> and cleaned on a regular basis, at least weekly, with all surfaces wiped from higher to lower.\u201d<\/p>\n<p>Also, the manual includes a list of criteria taken from the <strong>USP 797 publication<\/strong> in regards to low-risk compounded sterile products preparation which includes the use of an <strong><em>ISO Class 5 or better laminar flow hood<\/em><\/strong> for air quality.<\/p>\n<p>Ultimately, any healthcare provider that prepares IV bags for vitamin\/nutrient therapy must ensure that a safe, uncontaminated product is being used on each patient. This is accomplished through standard aseptic laboratory techniques, coupled with a preparation environment that is under positive pressure to reduce the number of contaminants in the air.<\/p>\n<h2>Benchtop Portable Clean Room Hoods<\/h2>\n<p><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV1.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV1-1024x805.jpg\" alt=\"IV Bag Preparation\" width=\"680\" height=\"535\" class=\"aligncenter size-large wp-image-335073\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV1-1024x805.jpg 1024w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV1-300x236.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV1-768x604.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV1.jpg 1074w\" sizes=\"(max-width: 680px) 100vw, 680px\" \/><\/a> <a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv6-edit.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv6-edit-235x300.jpg\" alt=\"\" width=\"300\" height=\"383\" class=\"alignleft size-medium wp-image-335189\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv6-edit-235x300.jpg 235w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv6-edit-768x979.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv6-edit-803x1024.jpg 803w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/iv6-edit.jpg 1177w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>The <strong>Sentry Air Systems 24-inch Wide Laminar Flow Hood<\/strong> <a href=\"https:\/\/www.sentryair.com\/specs\/24in%20Positive%20Pressure%20Hood.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=24-PCR-blog\" rel=\"noopener noreferrer\" target=\"_blank\">[SS-324-PCR]<\/a> is an <strong><em>ISO Class 5-rated positive-pressure hood<\/em><\/strong> designed to protect the IV bag preparation process being performed within the hood from outside ambient air. The fan\/motor housing sits atop the hood enclosure and draws ambient air into a dual-stage filter chamber outfitted with a pre-filter and main HEPA filter, which capture up to 99.97% of particles down to 0.3 microns.<\/p>\n<p>Sentry Air Portable Clean Room Hoods are an economical and easy-to-incorporate engineering safety control solution for protecting the process of IV bag preparation from contaminated ambient air.  Constructed of high-density polyethylene, polycarbonate, and acrylic, the hood enclosure is both durable and lightweight, while the smooth surfaces make cleaning quick and easy.<\/p>\n<p>The system also features energy-efficiency and quiet and low maintenance operation. A variable speed controller for air volume management and fluorescent light are included with this unit. An optional UV light is also available for sterilization purposes.<\/p>\n<p>To see our complete line of Portable Clean Room Hoods, please visit the <a href=\"https:\/\/www.sentryair.com\/pcrapp.htm?utm_source=Blog&amp;utm_medium=blog&amp;utm_campaign=PCR-All-Blog\" rel=\"noopener noreferrer\" target=\"_blank\">Sentry Air Systems website<\/a>.<\/p>\n<h3>To learn more about our line of Portable Clean Rooms and how they can help you with IV bag preparation, please contact us today!<\/h3>\n<p><a href=\"mailto:sales@sentryair.com\" rel=\"noopener noreferrer\" target=\"_blank\">sales@sentryair.com<\/a> \u2022 1.800.799.4609 \u2022 <a href=\"https:\/\/www.sentryair.com\/?utm_source=Blog&amp;utm_medium=blog&amp;utm_campaign=BlogToWebsiteCount\" rel=\"noopener noreferrer\" target=\"_blank\">www.sentryair.com<\/a><\/p>\n<h2>Sources<\/h2>\n<p><a name=\"Source1\"><\/a>1. \u201cWhat is IV Vitamin Infusion.\u201d Age-less Weigh-less. <a href=\"https:\/\/www.ageweighless.com\/iv-vitamin-infusion\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/www.ageweighless.com\/iv-vitamin-infusion<\/a>.<\/p>\n<p><a name=\"Source2\"><\/a>2. \u201cIntravenous Vitamin &amp; Nutrient Infusion Therapy.\u201d Wycoff Wellness. <a href=\"http:\/\/www.wycoffwellness.com\/treatments\/intravenous-vitamin-nutrient-infusion-therapy\" rel=\"noopener noreferrer\" target=\"_blank\">http:\/\/www.wycoffwellness.com\/treatments\/intravenous-vitamin-nutrient-infusion-therapy<\/a>.<\/p>\n<p><a name=\"Source3\"><\/a>3. Huber, Colleen. Best Practices: Guidelines for IV Preparation. 20 Feb 2015.  <a href=\"https:\/\/naturopathicstandards.org\/best-practices-guidelines-for-iv-preparation\/\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/naturopathicstandards.org\/best-practices-guidelines-for-iv-preparation\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Medical professionals and naturopathic\/holistic doctors have utilized IV vitamin\/nutrient therapies for many years as a more natural approach to treating chronic conditions in patients. As opposed to oral medications or supplements that travel through the body\u2019s digestive system, whereby diminishing absorption capabilities, IV therapy delivers optimal levels of the necessary vitamins\/supplements directly to the bloodstream;&#8230;  <a class=\"excerpt-read-more btn btn-primary\" style=\"display:block; color: #fff;  margin-top: 10px; max-width:120px;\" href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/\" title=\"Read IV Bag Preparation Best Practices Utilizing ISO Class 5 Laminar Flow Hoods\">Learn More<\/a><\/p>\n","protected":false},"author":2,"featured_media":335074,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1069,1006],"tags":[],"class_list":["post-334722","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-medical","category-portable-clean-room"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IV Bag Preparation Best Practices - ISO Class 5 Laminar Flow Hoods<\/title>\n<meta name=\"description\" content=\"To ensure patient safety, IV bag preparation must be infused in a sterile ISO Class 5 laminar flow hood or portable clean room.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IV Bag Preparation Best Practices - ISO Class 5 Laminar Flow Hoods\" \/>\n<meta property=\"og:description\" content=\"To ensure patient safety, IV bag preparation must be infused in a sterile ISO Class 5 laminar flow hood or portable clean room.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/\" \/>\n<meta property=\"og:site_name\" content=\"Sentry Air Systems, Inc.\" \/>\n<meta property=\"article:published_time\" content=\"2018-10-24T21:27:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-10T19:14:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"976\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sentryair\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sentryair\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/\",\"url\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/\",\"name\":\"IV Bag Preparation Best Practices - ISO Class 5 Laminar Flow Hoods\",\"isPartOf\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg\",\"datePublished\":\"2018-10-24T21:27:10+00:00\",\"dateModified\":\"2021-02-10T19:14:56+00:00\",\"author\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\"},\"description\":\"To ensure patient safety, IV bag preparation must be infused in a sterile ISO Class 5 laminar flow hood or portable clean room.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#primaryimage\",\"url\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg\",\"contentUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg\",\"width\":1500,\"height\":976,\"caption\":\"IV Bag Preparation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sentryair.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IV Bag Preparation Best Practices Utilizing ISO Class 5 Laminar Flow Hoods\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\",\"url\":\"https:\/\/www.sentryair.com\/blog\/\",\"name\":\"Sentry Air Systems, Inc.\",\"description\":\"Air Purification Systems, Ductless Hoods &amp; Fume Extractors\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\",\"name\":\"sentryair\",\"sameAs\":[\"http:\/\/www.sentryair.com\"],\"url\":\"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IV Bag Preparation Best Practices - ISO Class 5 Laminar Flow Hoods","description":"To ensure patient safety, IV bag preparation must be infused in a sterile ISO Class 5 laminar flow hood or portable clean room.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/","og_locale":"en_US","og_type":"article","og_title":"IV Bag Preparation Best Practices - ISO Class 5 Laminar Flow Hoods","og_description":"To ensure patient safety, IV bag preparation must be infused in a sterile ISO Class 5 laminar flow hood or portable clean room.","og_url":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/","og_site_name":"Sentry Air Systems, Inc.","article_published_time":"2018-10-24T21:27:10+00:00","article_modified_time":"2021-02-10T19:14:56+00:00","og_image":[{"width":1500,"height":976,"url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg","type":"image\/jpeg"}],"author":"sentryair","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sentryair","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/","url":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/","name":"IV Bag Preparation Best Practices - ISO Class 5 Laminar Flow Hoods","isPartOf":{"@id":"https:\/\/www.sentryair.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#primaryimage"},"image":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg","datePublished":"2018-10-24T21:27:10+00:00","dateModified":"2021-02-10T19:14:56+00:00","author":{"@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5"},"description":"To ensure patient safety, IV bag preparation must be infused in a sterile ISO Class 5 laminar flow hood or portable clean room.","breadcrumb":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#primaryimage","url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg","contentUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2018\/10\/IV3.jpg","width":1500,"height":976,"caption":"IV Bag Preparation"},{"@type":"BreadcrumbList","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/medical\/iv-bag-preparation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sentryair.com\/blog\/"},{"@type":"ListItem","position":2,"name":"IV Bag Preparation Best Practices Utilizing ISO Class 5 Laminar Flow Hoods"}]},{"@type":"WebSite","@id":"https:\/\/www.sentryair.com\/blog\/#website","url":"https:\/\/www.sentryair.com\/blog\/","name":"Sentry Air Systems, Inc.","description":"Air Purification Systems, Ductless Hoods &amp; Fume Extractors","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5","name":"sentryair","sameAs":["http:\/\/www.sentryair.com"],"url":"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334722"}],"collection":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/comments?post=334722"}],"version-history":[{"count":11,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334722\/revisions"}],"predecessor-version":[{"id":336500,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334722\/revisions\/336500"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/media\/335074"}],"wp:attachment":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/media?parent=334722"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/categories?post=334722"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/tags?post=334722"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}