{"id":334986,"date":"2019-02-13T15:57:50","date_gmt":"2019-02-13T15:57:50","guid":{"rendered":"https:\/\/www.sentryair.com\/blog\/?p=334986"},"modified":"2023-08-23T17:09:03","modified_gmt":"2023-08-23T17:09:03","slug":"laboratory-fume-hoods","status":"publish","type":"post","link":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/","title":{"rendered":"Laboratory Fume Hoods"},"content":{"rendered":"<div style=\"width: 960px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/DCH2_340_labhoods-sentryair.jpg\"><img decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/DCH2_340_labhoods-sentryair.jpg\" alt=\"Laboratory Fume Hoods\" width=\"950\" class=\"size-large\"><\/a><p class=\"wp-caption-text\">Laboratory Fume Hoods help protect the operator from inhaling harmful fumes and particulate during applications such as rotary evaporation.<\/p><\/div>\n<p>&nbsp;<br \/>\nLaboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases. Through inhalation, harmful fumes directly enter the blood stream and small particles may become embedded deep within the lungs <a href=\"#Source1\">(Ref. 1)<\/a>. A laboratory fume hood reduces exposure by containing the fumes and particulate dispersed during an experiment and a powerful fan diverts the airflow into a filter chamber or into external ductwork to be released outside the building. Ductless models filter the air releasing it back into the external room. By filtering the air, ductless fume hoods also provide environmental safety by removing harmful fumes before releasing the air back into the room.<\/p>\n<div style=\"clear: both;\"><\/div>\n<div style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/LaboratoryFumeHoods-DSC_0774-edit.jpg\"><img decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/LaboratoryFumeHoods-DSC_0774-edit.jpg\" alt=\"Laboratory Fume Hoods\" width=\"300\" class=\"size-medium\"><\/a><p class=\"wp-caption-text\">Fume Hoods help provide respiratory hazard control while working with different chemicals.<\/p><\/div>\n<h2>When to use a fume hood?<\/h2>\n<p>Laboratory fume hoods must be used when conducting experiments with toxic, flammable, carcinogenic, odorous, or dusty materials. This includes chemicals or materials with at least one of the following attributes:<\/p>\n<p>\u2022 <strong>Acute toxicity<\/strong> \u2013 short term exposure causes organ damage or fatality <a href=\"#Source2\">(Ref. 2)<\/a><br \/>\n\u2022 <strong>Reproductive toxins<\/strong> \u2013 chromosomal damage or effects on fetuses <a href=\"#Source2\">(Ref. 2)<\/a><br \/>\n\u2022 <strong>Flammable<\/strong> \u2013 health rating of 3 or 4 from National Fire Protection Association <a href=\"#Source3\">(Ref. 3)<\/a><br \/>\n\u2022 <strong>Carcinogenic<\/strong> \u2013 likely to cause cancer, regulated or listed by National Toxicology Program or International Research on Cancer <a href=\"#Source2\">(Ref. 2)<\/a><br \/>\n\u2022 <strong>Odorous<\/strong> \u2013 hazardous or nonhazardous <a href=\"#Source2\">(Ref. 2)<\/a><br \/>\n\u2022 <strong>Light dust producing<\/strong> \u2013 particularly with hazardous materials or irritating dust<\/p>\n<p>Other components of the experiment should be considered for the use of a laboratory fume hood, such as the procedure, probability of release of gases, the number and complexity of manipulations, and the skill level of the operator <a href=\"#Source4\">(Ref. 4)<\/a>.  Experiments should be designed to utilize laboratory fume hoods when necessary.<\/p>\n<p>Laboratory fume hoods should not be employed for biological agents or highly toxic materials <a href=\"#Source5\">(Ref. 5)<\/a>. Studies with biological agents, such as low to moderate risk pathogens and harmful microorganisms, must operate under portable clean rooms to protect contamination to the process. Comparatively, experiments with highly toxic materials must be completed with glove boxes to provide extra safety to the operator <a href=\"#Source4\">(Ref. 4)<\/a>.<\/p>\n<p>Proper usage of laboratory fume hoods protects the operator from respiratory exposure which may cause long-term harmful side effects. This chart below details the possible health effects from respiratory exposure for sample chemicals that are advised to be used under a laboratory fume hood. Please notice that many of the chemicals listed have OSHA permissible exposure limits (PELs) which OSHA legally requires employers follow for all employees.<\/p>\n<h3><strong>Common Chemical Respiratory Exposure Side Effects and OSHA Regulations <a href=\"#Source6\">(Ref. 6-10)<\/a> <\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"15%\"><strong>Chemical<\/strong><\/td>\n<td width=\"15%\"><strong>Compound<\/strong><\/td>\n<td width=\"15%\"><strong>OSHA PELs<\/strong><\/td>\n<td width=\"55%\"><strong>Health Effects<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Ammonia<\/td>\n<td>NH<sub>3<\/sub><\/td>\n<td>50 ppm<br \/>\n35 mg\/m<sup>3<\/sup><\/td>\n<td>Sinusitis, upper airway irritation, and eye irritation, severe injury or death.<\/td>\n<\/tr>\n<tr>\n<td>Arsine<\/td>\n<td>C<sub>18<\/sub>H<sub>14<\/sub>AsCl<\/td>\n<td>0.05 ppm<br \/>\n0.2 mg\/m<sup>3<\/sup><\/td>\n<td>Confusion, drowsiness, fatigue, headache, muscle cramps, nausea, vomiting, and\/or abdominal pain, rapid breathing, red or dark urine, shortness of breath, weakness, jaundice<\/td>\n<\/tr>\n<tr>\n<td>Carbon Monoxide<\/td>\n<td>CO<\/td>\n<td>50 ppm<br \/>\n55 mg\/m<sup>3<\/sup><\/td>\n<td>Poisonous gas, central nervous system damage and asphyxiation<\/td>\n<\/tr>\n<tr>\n<td>Chlorine<\/td>\n<td>Cl<sub>2<\/sub><\/td>\n<td>1 ppm<br \/>\n3 mg\/m<sup>3<\/sup><\/td>\n<td>Toxic by inhalation, Bronchitis or chronic lung conditions<\/td>\n<\/tr>\n<tr>\n<td>Chloroform<\/td>\n<td>CHCl<sub>3<\/sub><\/td>\n<td>50 ppm<br \/>\n240 mg\/m<sup>3<\/sup><\/td>\n<td>Suspected carcinogen, impaired liver function, cardiac arrhythmia, nausea and central nervous system dysfunction<\/td>\n<\/tr>\n<tr>\n<td>Fluorine<\/td>\n<td>F<sub>2<\/sub><\/td>\n<td>0.1 ppm<br \/>\n0.2 mg\/m<sup>3<\/sup><\/td>\n<td>Poisonous; may be fatal if inhaled. Vapor extremely irritating. Contact may cause burns to skin and eyes<\/td>\n<\/tr>\n<tr>\n<td>Formaldehyde<\/td>\n<td>H<sub>2<\/sub>CO<\/td>\n<td>0.75 ppm<br \/>\n(Cal OSHA)<\/td>\n<td>Irritation eyes, nose, throat, respiratory system, lacrimation (discharge of tears), cough, wheezing, potential occupational carcinogen<\/td>\n<\/tr>\n<tr>\n<td>Hydrochloric Acid<\/td>\n<td>HCl<\/td>\n<td>&#8211;<\/td>\n<td>Coughing, choking, inflammation of the nose, throat, and upper respiratory tract, and in severe cases, pulmonary edema, circulatory system failure, and death<\/td>\n<\/tr>\n<tr>\n<td>Hydrogen Selenide<\/td>\n<td>H<sub>2<\/sub>Se<\/td>\n<td>0.05 ppm<br \/>\n0.2 mg\/m<sup>3<\/sup><\/td>\n<td>Fatal, extremely dangerous to life<\/td>\n<\/tr>\n<tr>\n<td>Hydrogen Sulfide<\/td>\n<td>H<sub>2<\/sub>S<\/td>\n<td>20 ppm<\/td>\n<td>Death, permanent injury, affects nervous system resulting in paralysis of respiratory centers<\/td>\n<\/tr>\n<tr>\n<td>Isopropyl Alcohol<\/td>\n<td>C<sub>3<\/sub>H<sub>8<\/sub>O<\/td>\n<td>400 ppm<\/td>\n<td>Generally safe in small amounts but long term exposure can result in headache, dizziness, vomiting, nausea, and unconsciousness<\/td>\n<\/tr>\n<tr>\n<td>Nickel Carbonyl<\/td>\n<td>C<sub>4<\/sub>NiO<sub>4<\/sub><\/td>\n<td>0.001 ppm<br \/>\n0.007 mg\/m<sup>3<\/sup><\/td>\n<td>Highly toxic, shortness of breath, chest tightness, paresthesia<\/td>\n<\/tr>\n<tr>\n<td>Nitrite<\/td>\n<td>NO<sub>2<\/sub><\/td>\n<td>Oxide:<br \/>\n25 ppm,<br \/>\n30 mg\/m<sup>3<\/sup><\/td>\n<td>Irritation to skin, eyes, and mucous membranes, severe injury, burns or death.<\/td>\n<\/tr>\n<tr>\n<td>Phosgene<br \/>\n(Carbonyl chloride)<\/td>\n<td>COCl<sub>2<\/sub><\/td>\n<td>0.1 ppm<br \/>\n0.4 mg\/m<sup>3<\/sup><\/td>\n<td>Coughing, burning sensation in the throat and eyes, watery eyes, blurred vision, difficulty breathing or shortness of breath, nausea and vomiting, skin contact can result in lesions similar to frostbite or burns<\/td>\n<\/tr>\n<tr>\n<td>Silane<\/td>\n<td>SiH<sub>4<\/sub><\/td>\n<td>&#8211;<\/td>\n<td>Skin, eye and respiratory irritant, dizziness, asphyxiation, toxic, burns, severe injury, frostbite<\/td>\n<\/tr>\n<tr>\n<td>Sulfuric Acid<\/td>\n<td>H<sub>2<\/sub>SO<sub>4<\/sub><\/td>\n<td>1 mg\/m<sup>3<\/sup><\/td>\n<td>Serious lung damage<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr>\n<h2>Ductless vs Ducted Laboratory Fume Hoods<\/h2>\n<div id=\"attachment_334992\" style=\"width: 1164px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/DuctlessVsDucted-revised.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-334992\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/DuctlessVsDucted-revised.jpg\" alt=\"Ductless vs Ducted Laboratory Fume Hoods\" width=\"1154\" height=\"512\" class=\"size-full wp-image-334992\"><\/a><p id=\"caption-attachment-334992\" class=\"wp-caption-text\">Ductless (left) and Ducted Laboratory Fume Hoods (right)<\/p><\/div>\n<p>&nbsp;<br \/>\nLaboratory fume hoods consist of two main types: ductless and ducted. Ductless fume hoods filter the air and release it back into the outside room. However, ducted fume hoods divert the air into an external duct system and release the unfiltered air outside of the building. Ductless laboratory fume hoods offer a number of benefits over ducted including:<\/p>\n<h4>Environmental Protection<\/h4>\n<p>By filtering and removing contaminants from the air, the system prevents harmful pollutants release into the atmosphere.<\/p>\n<h4>No Makeup Air Required<\/h4>\n<p>Ductless fume hoods filter the air and release it back into the room. This recirculation pattern eliminates the need to add makeup air, which is required with ducted fume hoods.<\/p>\n<h4>Energy Efficient<\/h4>\n<p>Due to the recirculating design, ductless fume hoods save energy by not wasting climate controlled air.<\/p>\n<h4>Minimal Maintenance<\/h4>\n<p>These dependable and reliable units only need regular filter maintenance for replacing saturated filters and regular cleaning to remove spills or residue.<\/p>\n<h4>Simple Installation<\/h4>\n<p>Because of the lack of expensive external ductwork, ductless fume hoods offer \u201cplug and play\u201d solutions without costly installation.<\/p>\n<h4>High Quality Filtration<\/h4>\n<p>All ductless fume hoods are available in a variety of high quality filters:<br \/>\n\u2022 <b>HEPA<\/b> \u2013 up to 99.97% efficiency on particles as small as 0.3 microns<br \/>\n\u2022 <b>ULPA<\/b> \u2013 up to 99.9995% efficiency on particles as small as 0.12 microns<br \/>\n\u2022 <b>ASHRAE<\/b> \u2013 up to 95% efficiency on particles as small as 0.5 microns<br \/>\n\u2022 <b>Activated carbon &amp; specialty-blended filters <\/b>(aldehyde, ammonia, acid gas, mercury)<\/p>\n<hr>\n<h2>Components of Laboratory Fume Hoods<\/h2>\n<p>See diagrams below for components of ductless and ducted laboratory fume hoods.<\/p>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h3><strong>Ductless Fume Hoods<\/strong><\/h3>\n<p><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-Diagram-LaboratoryFumeHoods-big.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-Diagram-LaboratoryFumeHoods-big-296x300.jpg\" alt=\"Components of Ductless Laboratory Fume Hoods\" width=\"296\" height=\"300\" class=\"alignleft size-medium wp-image-334998\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-Diagram-LaboratoryFumeHoods-big-296x300.jpg 296w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-Diagram-LaboratoryFumeHoods-big-768x780.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-Diagram-LaboratoryFumeHoods-big-1009x1024.jpg 1009w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-Diagram-LaboratoryFumeHoods-big.jpg 1388w\" sizes=\"(max-width: 296px) 100vw, 296px\" \/><\/a><\/p>\n<p><strong>Magnehelic Gauge<\/strong><br \/>\nThe magnehelic gauge measures the static pressure of the filter to help monitor the filter saturation. As the filter becomes more saturated, the pressure will increase and the gauge will move up. After a certain point, the filter must be changed to ensure proper filtration and protection.<\/p>\n<p><strong>Variable Speed Control<\/strong><br \/>\nThe variable speed control allows the operator to adjust the fan speed based on parameters of the experiment.<\/p>\n<\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h3><strong>Ducted Fume Hoods<\/strong><\/h3>\n<p><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-Diagram-LaboratoryFumeHoods-big.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-Diagram-LaboratoryFumeHoods-big-294x300.jpg\" alt=\"Components of Ducted Laboratory Fume Hoods\" width=\"294\" height=\"300\" class=\"alignleft size-medium wp-image-334999\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-Diagram-LaboratoryFumeHoods-big-294x300.jpg 294w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-Diagram-LaboratoryFumeHoods-big-768x783.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-Diagram-LaboratoryFumeHoods-big-1004x1024.jpg 1004w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-Diagram-LaboratoryFumeHoods-big.jpg 1387w\" sizes=\"(max-width: 294px) 100vw, 294px\" \/><\/a><br \/>\n<strong>Outlet Collar<\/strong><br \/>\nThe outlet collar connects to the external ductwork and fan system. The fan draws the fumes and particulate from under the hood through the outlet collar and external ductwork to be released outside of the building.<\/p>\n<\/div>\n<div style=\"clear: both;\"><\/div>\n<h3><strong>Both<\/strong><\/h3>\n<p><strong>Sash<\/strong><br \/>\nThe sash on a laboratory fume hood helps determine the airflow characteristics and controls the air velocity to adequately capture chemical vapors and particulate <a href=\"#Source3\">(Ref. 3)<\/a>.<\/p>\n<p><strong>Spill Tray<\/strong><br \/>\nSpill trays help prevent the spread of chemicals when spills or accidents occur during an experiment. Spill trays are an accessory and would be placed on the work surface as needed.<\/p>\n<hr>\n<h2>How do Laboratory Fume Hoods work?<\/h2>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h3><strong>Ductless Fume Hoods<\/strong><\/h3>\n<p><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-HowDoesitWork-LaboratoryFumeHoods-big.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-715x1024.jpg\" alt=\"How do Ductless Fume Hoods work?\" width=\"680\" height=\"974\" class=\"alignleft size-large wp-image-335006\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-715x1024.jpg 715w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-209x300.jpg 209w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-768x1100.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctlessFumeHood-HowDoesitWork-LaboratoryFumeHoods-big.jpg 1922w\" sizes=\"(max-width: 680px) 100vw, 680px\" \/><\/a><\/p>\n<p><strong>&#8211; Step 1 &#8211;<\/strong><br \/>\nOperator performs the process or experiment within the hood behind the sash to contain harmful fumes and particulate, preventing them from emitting into the ambient air. The powerful fan, located on top of the hood, draws in the fumes and particulate along with ambient air into the filter chamber.<\/p>\n<p><strong>&#8211; Step 2 &#8211;<\/strong><br \/>\nA pre-filter processes the air captures some of the particles.<\/p>\n<p><strong>&#8211; Step 3 &#8211;<\/strong><br \/>\nThe main filter processes the air in which the efficiency depends on the type of filter utilized (HEPA, ULPA, ASHRAE, Activated Carbon, or Specialty Blended).<\/p>\n<p><strong>&#8211; Step 4 &#8211;<\/strong><br \/>\nThe system releases the filtered air back into the room eliminating the need for duct work.<\/p>\n<\/div>\n<div style=\"width:50%;padding:0 10px 0 0;float:left;\">\n<h3><strong>Ducted Fume Hoods<\/strong><\/h3>\n<p><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-HowDoesitWork-LaboratoryFumeHoods-big.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-716x1024.jpg\" alt=\"How do ducted fume hoods work?\" width=\"680\" height=\"973\" class=\"alignleft size-large wp-image-335010\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-716x1024.jpg 716w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-210x300.jpg 210w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-HowDoesitWork-LaboratoryFumeHoods-big-768x1099.jpg 768w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/DuctedFumeHood-HowDoesitWork-LaboratoryFumeHoods-big.jpg 1921w\" sizes=\"(max-width: 680px) 100vw, 680px\" \/><\/a><\/p>\n<p><strong>&#8211; Step 1 &#8211;<\/strong><br \/>\nOperator conducts the process or experiment in the hood behind the sash to avoid exposure of harmful fumes and particulate.<\/p>\n<p><strong>&#8211; Step 2 &#8211;<\/strong><br \/>\nA powerful fan draws air through the outlet collar into external ductwork.<\/p>\n<p><strong>&#8211; Step 3 &#8211;<\/strong><br \/>\nThe system exhausts air to outside the building preventing operators from breathing harmful fumes and particulate.<\/p>\n<\/div>\n<div style=\"clear: both;\"><\/div>\n<hr>\n<h2>Proper Use and Safety Guidelines for Laboratory Fume Hoods Usage<\/h2>\n<p>To ensure protection from harmful chemical vapors and fumes, proper safety procedures must be implemented in the lab while using a laboratory fume hood.<\/p>\n<p>\u2022 Always make sure the laboratory fume hood is operating correctly before beginning the procedure <a href=\"#Source1\">(Ref. 1)<\/a>.<br \/>\n\u2022 Proper safety gear must be worn at all times including safety goggles, lab coats, and chemical safe gloves <a href=\"#Source11\">(Ref. 11)<\/a>.<br \/>\n\u2022 Keep face and heat outside of the sash at all times and limit the amount of time that hands and arms are working inside the sash <a href=\"#Source1\">(Ref. 1)<\/a>.<br \/>\n\u2022 Only keep necessary materials within the laboratory fume hood. Never use it for storage and keep the area from overcrowding for proper use <a href=\"#Source1\">(Ref. 1)<\/a>.<br \/>\n\u2022 Keep all materials 6\u201d (15 cm) within the hood to properly vent fumes and prevent seepage <a href=\"#Source3\">(Ref. 3)<\/a>.<br \/>\n\u2022 Minimize outside air flow by closing windows and doors as well as reducing traffic in front of the laboratory fume hood <a href=\"#Source11\">(Ref. 11)<\/a>.<br \/>\n\u2022 Only remove hazardous chemicals from the laboratory fume hood once the storage container is fully closed <a href=\"#Source4\">(Ref. 4)<\/a>.<\/p>\n<hr>\n<h2>Sentry Air Solutions Laboratory Fume Hoods<\/h2>\n<div id=\"attachment_335014\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/AirHawk_30inchsh_01A.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-335014\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/AirHawk_30inchsh_01A.jpg\" alt=\"30 in AirHawk Ductless Fume Hood\" width=\"300\" class=\"size-medium wp-image-335014\"><\/a><p id=\"caption-attachment-335014\" class=\"wp-caption-text\"><a href=\"https:\/\/www.sentryair.com\/ductless-fume-hood.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=ductless-fume-hood-labs-blog\" target=\"_blank\" rel=\"noopener noreferrer\">30\u201d AirHawk Ductless Fume Hood<\/a><\/p><\/div>\n<h3><strong>AirHawk \u2013 Advanced Ductless Laboratory Fume Hood <\/strong><\/h3>\n<p>The latest in ductless fume hood technology, the AirHawk offers a user-friendly control panel complete with adjustable light and fan controls with digital displays for air pressure and runtime. The AirHawk features a 1400 LUX LED light, the brightest in the fume hood industry, providing superior visibility with an adjustable control. The adjustable fan control allows the operator to vary the fan speed and make note of settings to optimize experimental conditions. The air pressure digital display uses a precision solid-state pressure sensor to measure the static pressure on the particulate filters. Over time as the filter becomes saturated, the air pressure display will increase and once it reaches a certain pressure the filter will need to be changed. The runtime digital display shows in hours how long the hood has been in use. This feature will help with filter maintenance schedules with the ability to reset after filter replacement. The AirHawk provides both operator and environmental safety with helpful technological features to aide in everyday laboratory work. Standard sizes of the AirHawk available are 30\u201d, 40\u201d and 50\u201d with in between sizes available made custom.<\/p>\n<p><a href=\"https:\/\/www.sentryair.com\/ductless-fume-hood.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=ductless-fume-hood-labs-blog\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/LaboratoryFumeHoods-LearnMore-button.png\" alt=\"Learn More AirHawk Laboratory Fume Hoods\" width=\"150\" height=\"38\" class=\"alignleft\"><\/a><\/p>\n<div style=\"clear: both;\"><\/div>\n<hr>\n<div id=\"attachment_335017\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/SS-330-DCH.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-335017\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/SS-330-DCH.jpg\" alt=\"30\u201d Ductless Fume Hood\" width=\"300\" class=\"size-medium wp-image-335017\"><\/a><p id=\"caption-attachment-335017\" class=\"wp-caption-text\"><a href=\"https:\/\/www.sentryair.com\/ductless-fume-hood.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=ductless-fume-hood-labs-blog\" target=\"_blank\" rel=\"noopener noreferrer\">30\u201d Ductless Fume Hood<\/a><\/p><\/div>\n<h3><strong>Ductless Laboratory Fume Hoods<\/strong><\/h3>\n<p>The standard ductless fume hoods offer all the benefits of a ductless unit in a simple, practical and economical package. These self-contained circulating respiratory protection devices come in a wide variety of sizes: 12\u201d, 18\u201d, 24\u201d, 30\u201d, 40\u201d, 50\u201d, 60\u201d and 70\u201d. The 40\u201d and 70\u201d models are available with high flow capabilities. The standard ductless fume hood comes with a variable speed controller (115 V only), anti-static vinyl curtains, velometer, and bright fluorescent light. Optional components include magnehelic gage, hour counter, and spill tray.<\/p>\n<p><em>Custom Options available including:<\/em><br \/>\n\u2022 Hood material and colors ( i.e. stainless steel hoods, all clear, etc)<br \/>\n\u2022 Custom sizes and dimensions<br \/>\n\u2022 Slip-hatches<br \/>\n\u2022 Multiple points of entry<br \/>\n\u2022 Anti-static material (for ESD-safe required electrical work)<br \/>\n\u2022 Mounting options<br \/>\n\u2022 Sink &amp; Custom cutouts<br \/>\n\u2022 Accessories for hanging equipment<br \/>\n\u2022 Multiple folding hinged lids<br \/>\n\u2022 Varied blower configurations<\/p>\n<p><a href=\"https:\/\/www.sentryair.com\/ductless-fume-hood.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=ductless-fume-hood-labs-blog\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/LaboratoryFumeHoods-LearnMore-button.png\" alt=\"Learn More Ductless Laboratory Fume Hoods\" width=\"150\" height=\"38\" class=\"alignleft\"><\/a><\/p>\n<div style=\"clear: both;\"><\/div>\n<hr>\n<div id=\"attachment_335018\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/SS-324-E.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-335018\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2023\/08\/SS-324-E.jpg\" alt=\"24\u201d Ducted Fume Hood\" width=\"300\" class=\"size-medium wp-image-335018\"><\/a><p id=\"caption-attachment-335018\" class=\"wp-caption-text\"><a href=\"https:\/\/www.sentryair.com\/ducted-fume-hood.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=ducted-fume-hood-labs-blog\" target=\"_blank\" rel=\"noopener noreferrer\">24\u201d Ducted Fume Hood<\/a><\/p><\/div>\n<h3><strong>Ducted Laboratory Fume Hoods<\/strong><\/h3>\n<p>For some applications where ducted laboratory fume hoods are required, our line provides an enclosed workspace to protect the respiratory zone of the operator from inhalation of hazardous fumes and particulate. Certain universities and other laboratories require the use of ducted laboratory fume hoods. The 6\u201d outlet collar connects to external ductwork and fan system to move fumes and particulate from under the hood, through the duct to release outside the building. The ducted laboratory fume hoods come in a wide variety of sizes including 18\u201d, 24\u201d, 30\u201d, 40\u201d, 50\u201d, 60\u201d and 70\u201d. Similar to the ductless units, the duct laboratory fume hoods have an assortment of custom options including material, dimensions, cutouts for sinks and instruments, and multiple work entry configurations. Optional accessories include spill trays, velometer, cleaning products, and a blacklight. It is important to note that the duct laboratory fume hoods do not provide environmental protection and do not filter the air before releasing outdoors.  SAS ducted laboratory fume hoods do not include external ductwork and fan but we can help you choose a system for this hood.<\/p>\n<p><a href=\"https:\/\/www.sentryair.com\/ducted-fume-hood.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=ducted-fume-hood-labs-blog\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/LaboratoryFumeHoods-LearnMore-button.png\" alt=\"Learn More Ducted Laboratory Fume Hoods\" width=\"150\" height=\"38\" class=\"alignleft\"><\/a><\/p>\n<div style=\"clear: both;\"><\/div>\n<hr>\n<h3><strong>Consult our solutions experts today to help you select a fume hood for your laboratory!<\/strong><\/h3>\n<p><a href=\"https:\/\/www.sentryair.com\/contact-us.htm?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=Contactus-blog\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/LaboratoryFumeHoods-TalktoExpert-button.png\" alt=\"\" width=\"150\" height=\"38\" class=\"alignleft\"><\/a>   <a href=\"mailto:sales@sentryair.com\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Button-EmailUs-LaboratoryFumeHoods.png\" alt=\"Email Us - Laboratory Fume Hoods\" width=\"150\" height=\"38\" class=\"alignleft\"><\/a>   <a href=\"https:\/\/www.sentryair.com\/?utm_source=Blog&amp;utm_medium=blog&amp;utm_campaign=BlogToWebsiteCount\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/LaboratoryFumeHoods-Website-button.png\" alt=\"Visit Website - Laboratory Fume hoods\" width=\"150\" height=\"38\" class=\"alignleft\"><\/a><\/p>\n<div style=\"clear: both;\"><\/div>\n<h3><strong>Call us today at 1-800-799-4609<br \/>\n<\/strong><\/h3>\n<hr>\n<h4>References<\/h4>\n<p><a id=\"Source1\"><\/a>1. \u201cUse of the Laboratory Fume-hood.\u201d<em> University of Wollongong.<\/em> Apr 2009.  <a href=\"https:\/\/smah.uow.edu.au\/content\/groups\/public\/@web\/@sci\/@chem\/documents\/doc\/uow059174.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/smah.uow.edu.au\/content\/groups\/public\/@web\/@sci\/@chem\/documents\/doc\/uow059174.pdf<\/a>.<\/p>\n<p><a id=\"Source2\"><\/a>2. \u201cAttachment A: Particularly Hazardous Substances Definitions.\u201d<em> UCLA Policy 907. <\/em> <a href=\"https:\/\/ehs.ucsc.edu\/programs\/research-safety\/documents\/ucla_phs_defn.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/ehs.ucsc.edu\/programs\/research-safety\/documents\/ucla_phs_defn.pdf<\/a>.<\/p>\n<p><a id=\"Source3\"><\/a>3. \u201cFume Hood Questions and Answers.\u201d<em> University of Colorado at Boulder: Department of Environmental Health and Safety.<\/em> Nov 2008. <a href=\"https:\/\/www.colorado.edu\/ehs\/sites\/default\/files\/attached-files\/fume-hood-qanda.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/www.colorado.edu\/ehs\/sites\/default\/files\/attached-files\/fume-hood-qanda.pdf<\/a>.<\/p>\n<p><a id=\"Source4\"><\/a>4. \u201cLaboratory Equipment and Engineering Controls.\u201d <em>Princeton University: Environmental Health &amp; Safety.<\/em> <a href=\"https:\/\/ehs.princeton.edu\/laboratory-research\/laboratory-safety\/laboratory-equipment-and-engineering\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/ehs.princeton.edu\/laboratory-research\/laboratory-safety\/laboratory-equipment-and-engineering<\/a>.<\/p>\n<p><a id=\"Source5\"><\/a>5. \u201cChemical Fume Hoods Overview.\u201d <em>UC San Diego.<\/em> 8 Jun 2018. <a href=\"https:\/\/blink.ucsd.edu\/safety\/research-lab\/chemical\/hoods\/index.html#Learn-more\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/blink.ucsd.edu\/safety\/research-lab\/chemical\/hoods\/index.html#Learn-more<\/a>.<\/p>\n<p><a id=\"Source6\"><\/a>6. \u201cArsine\u201d, \u201cPhosgene\u201d. <em>Centers for Disease Control and Prevention.<\/em> <a href=\"https:\/\/emergency.cdc.gov\/\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/emergency.cdc.gov\/<\/a>.<\/p>\n<p><a id=\"Source7\"><\/a>7. \u201cAmmonia\u201d, \u201cChloroform\u201d, \u201cFluorine\u201d, \u201cFormaldehyde\u201d, \u201cHydrochloric Acid\u201d, \u201cHydrogen Selenide\u201d, \u201cHydrogen Sulfide\u201d,  \u201cNitrite\u201d, \u201cSilane\u201d, \u201cSulfuric Acid\u201d.  <em>Pub Chem: US National Library of Medicine.<\/em> <a href=\"https:\/\/pubchem.ncbi.nlm.nih.gov\/\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/pubchem.ncbi.nlm.nih.gov\/ <\/a>.<\/p>\n<p><a id=\"Source8\"><\/a>8. Dean BS. Krenzelok EP. Kurta DL. \u201cAcute Nickel Carbonyl Poisoning.\u201d <em>Am J Erg Med.<\/em> 1993. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/8383493\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/8383493<\/a>.<\/p>\n<p><a id=\"Source9\"><\/a>9. \u201cIsopropyl Alcohol Safety Tips from MSDSonline.\u201d <em>MSDS online.<\/em> 20 Feb 2015. <a href=\"https:\/\/www.msdsonline.com\/2015\/02\/20\/isopropyl-alcohol-safety-tips-from-msdsonline\/\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/www.msdsonline.com\/2015\/02\/20\/isopropyl-alcohol-safety-tips-from-msdsonline\/<\/a>.<\/p>\n<p><a id=\"Source10\"><\/a>10. Occupational Safety and Health Administration. \u201cOSHA Annotated Table Z-1,\u201d <a href=\"https:\/\/www.osha.gov\/dsg\/annotated-pels\/tablez-1.html\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/www.osha.gov\/dsg\/annotated-pels\/tablez-1.html<\/a>.<\/p>\n<p><a id=\"Source11\"><\/a>11. \u201cGuidelines for the Safe Use of Laboratory Fume Hoods.\u201d <em>Florida International University: Environmental Health &amp; Safety. <\/em>Oct 2016. <a href=\"https:\/\/ehs.fiu.edu\/_assets\/docs\/chemical\/fume-hoods-guidelines.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">https:\/\/ehs.fiu.edu\/_assets\/docs\/chemical\/fume-hoods-guidelines.pdf<\/a>.<\/p>\n<hr>\n<h4>Related Blogs<\/h4>\n<p>\u2022 <a href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/laboratories\/rotary-evaporator-fume-control\/\">Rotary Evaporator Fume Control<\/a><br \/>\n\u2022 <a href=\"https:\/\/www.sentryair.com\/blog\/filters\/using-filtration-to-help-address-common-exhaust-hood-issues-exhaust-filter-box\/\">Using Filtration to Help Address Common Exhaust Hood Issues \u2013 Exhaust Filter Box<\/a><br \/>\n\u2022 <a href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/hydrochloric-acid-vapor-health-risks\/\">Hydrochloric acid health risks: vapor, mist, and fume inhalation<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; Laboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases. Through inhalation, harmful fumes directly enter the blood stream and small particles may become embedded deep within the lungs (Ref. 1). A laboratory fume hood reduces exposure by containing the fumes and particulate dispersed during an experiment and a&#8230;  <a class=\"excerpt-read-more btn btn-primary\" style=\"display:block; color: #fff;  margin-top: 10px; max-width:120px;\" href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/\" title=\"Read Laboratory Fume Hoods\">Learn More<\/a><\/p>\n","protected":false},"author":2,"featured_media":334987,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1186,748,84,2837,2838,1059,1],"tags":[],"class_list":["post-334986","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-chemical-solvents","category-ducted-fume-hood","category-ductless-fume-hood","category-fume-control-extraction","category-health-risks-safety","category-laboratories","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Laboratory Fume Hoods | Laboratory Fume Control - Sentry Air Systems<\/title>\n<meta name=\"description\" content=\"Laboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases through containment and filtration.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Laboratory Fume Hoods | Laboratory Fume Control - Sentry Air Systems\" \/>\n<meta property=\"og:description\" content=\"Laboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases through containment and filtration.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/\" \/>\n<meta property=\"og:site_name\" content=\"Sentry Air Systems, Inc.\" \/>\n<meta property=\"article:published_time\" content=\"2019-02-13T15:57:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-23T17:09:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods-1024x682.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"682\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sentryair\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sentryair\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/\",\"url\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/\",\"name\":\"Laboratory Fume Hoods | Laboratory Fume Control - Sentry Air Systems\",\"isPartOf\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods.jpg\",\"datePublished\":\"2019-02-13T15:57:50+00:00\",\"dateModified\":\"2023-08-23T17:09:03+00:00\",\"author\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\"},\"description\":\"Laboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases through containment and filtration.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#primaryimage\",\"url\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods.jpg\",\"contentUrl\":\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods.jpg\",\"width\":2716,\"height\":1810,\"caption\":\"laboratory fume hoods\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sentryair.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Laboratory Fume Hoods\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\",\"url\":\"https:\/\/www.sentryair.com\/blog\/\",\"name\":\"Sentry Air Systems, Inc.\",\"description\":\"Air Purification Systems, Ductless Hoods &amp; Fume Extractors\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5\",\"name\":\"sentryair\",\"sameAs\":[\"http:\/\/www.sentryair.com\"],\"url\":\"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Laboratory Fume Hoods | Laboratory Fume Control - Sentry Air Systems","description":"Laboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases through containment and filtration.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/","og_locale":"en_US","og_type":"article","og_title":"Laboratory Fume Hoods | Laboratory Fume Control - Sentry Air Systems","og_description":"Laboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases through containment and filtration.","og_url":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/","og_site_name":"Sentry Air Systems, Inc.","article_published_time":"2019-02-13T15:57:50+00:00","article_modified_time":"2023-08-23T17:09:03+00:00","og_image":[{"width":1024,"height":682,"url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods-1024x682.jpg","type":"image\/jpeg"}],"author":"sentryair","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sentryair","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/","url":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/","name":"Laboratory Fume Hoods | Laboratory Fume Control - Sentry Air Systems","isPartOf":{"@id":"https:\/\/www.sentryair.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#primaryimage"},"image":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods.jpg","datePublished":"2019-02-13T15:57:50+00:00","dateModified":"2023-08-23T17:09:03+00:00","author":{"@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5"},"description":"Laboratory fume hoods provide operator and environmental protection from hazardous fumes, particulate, and other gases through containment and filtration.","breadcrumb":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#primaryimage","url":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods.jpg","contentUrl":"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2019\/02\/Lab-other-LaboratoryFumeHoods.jpg","width":2716,"height":1810,"caption":"laboratory fume hoods"},{"@type":"BreadcrumbList","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/chemical-solvents\/laboratory-fume-hoods\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sentryair.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Laboratory Fume Hoods"}]},{"@type":"WebSite","@id":"https:\/\/www.sentryair.com\/blog\/#website","url":"https:\/\/www.sentryair.com\/blog\/","name":"Sentry Air Systems, Inc.","description":"Air Purification Systems, Ductless Hoods &amp; Fume Extractors","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/799b2bc2f157a0b1c3ef4121378f9ee5","name":"sentryair","sameAs":["http:\/\/www.sentryair.com"],"url":"https:\/\/www.sentryair.com\/blog\/author\/sentryair\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334986"}],"collection":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/comments?post=334986"}],"version-history":[{"count":37,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334986\/revisions"}],"predecessor-version":[{"id":338273,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/334986\/revisions\/338273"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/media\/334987"}],"wp:attachment":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/media?parent=334986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/categories?post=334986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/tags?post=334986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}