{"id":42,"date":"2012-03-27T16:04:00","date_gmt":"2012-03-27T16:04:00","guid":{"rendered":"http:\/\/sentryair.com\/blog\/?p=42"},"modified":"2013-05-14T17:52:54","modified_gmt":"2013-05-14T17:52:54","slug":"part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding","status":"publish","type":"post","link":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/","title":{"rendered":"Part Two &#8211; Compounding Pharmacies: Engineering Controls for Non-sterile Compounding"},"content":{"rendered":"<div>This is the second article in a series of three that addresses the <a href=\"http:\/\/www.ok.gov\/OSBP\/documents\/law10.pdf\">Oklahoma Pharmacy Law<\/a> Book\u2019s airflow and filtration requirements for containment hood systems within compounding pharmacies.<\/div>\n<p><P><\/p>\n<div>The <a href=\"http:\/\/sentryairsystems.blogspot.com\/2012\/03\/part-one-compounding-pharmacies.html\">first article<\/a> in the series discusses the generic qualities of air flow within cabinets and hoods noted in the law book. It also identifies some of the organizations that establish performance standards for respiratory safety equipment such as cabinets, hoods and isolators.<\/div>\n<p><P><\/p>\n<div>The <a href=\"http:\/\/sentryair.com\/blog\/respiratory-safety\/three-part-series-compounding-pharmacy-respiratory-safety-regulations\/\">third article<\/a> and final post in this series discusses the law book\u2019s equipment specifications for compounding sterile products.<\/div>\n<p><P><\/p>\n<div style=\"margin-bottom: 0in; margin-left: 1.0in; margin-right: 53.3pt; margin-top: 0in;\"><strong><span style=\"font-family: Arial; font-size: 11pt;\">NOTE: Cabinets, clean rooms, hoods, and isolators have varied functionality and have differing roles in the compounding pharmacy. See your state\u2019s pharmacy laws for guidance on the role these devices play in your practice. Click <a href=\"http:\/\/www.nabp.net\/boards-of-pharmacy\/\">here<\/a> for links to the pharmacy boards listed on the National Association of Pharmacy Boards (NAPB) website.<\/span><\/strong><\/div>\n<p><P><\/p>\n<div><strong><span style=\"font-family: Arial; font-size: 11pt;\">Compounding non-sterile hazardous drugs<\/span><\/strong><span style=\"font-family: Arial;\">.<\/span> In the law book, section 535:15-10-14 contains specific criteria for handling non-sterile <a href=\"http:\/\/www.cdc.gov\/niosh\/docs\/2010-167\/\">hazardous drugs listed by NIOSH<\/a>, the National Institute for Occupational Safety and Health.<\/div>\n<p><P><\/p>\n<div>In the table below, you will find three columns. The first column indicates the engineering control recommended in the Oklahoma Pharmacy Law Book for Non-Sterile Compounding (i.e., Class 1 Biological Safety Cabinet (BSC), Powder Containment Hood, or Isolator). In the second column you\u2019ll find the NSF definition of a Class 1 BSC and HEPA Filter. The third column shows how <a href=\"http:\/\/www.sentryair.com\/pharmaceutical.htm\">Sentry Air Powder Containment Hoods<\/a> meet or exceed these requirements.<\/div>\n<p><P><\/p>\n<div>Our pharmacy customers use our ductless hoods for weighing powder, filling capsules, compounding creams, and a variety of additional non-sterile compounding applications that require both containment and filtration.<\/div>\n<p><P><\/p>\n<div><strong><span style=\"color: red;\">IMPORTANT:<\/span><\/strong><span style=\"color: red;\"> Sentry Air Systems provides this information as a customer service. All information should be independently verified. The category of material being handled \u2013 for example, hazardous, sterile, non-sterile \u2013 and nature of the material \u2013 liquid, powder, gel, for example &#8212; require different types of engineered controls to protect products, people and the work environment. <em>A certified industrial hygienist should be consulted to determine the best configuration of primary and secondary engineering controls for your pharmacy. <\/em><\/span><\/div>\n<p><P><\/p>\n<table style=\"border-collapse: collapse; border-color: initial; border-image: initial; border-width: initial; width: 595px; border-style: none;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"mso-yfti-firstrow: yes; mso-yfti-irow: 0; page-break-inside: avoid;\">\n<td style=\"background: #333399; border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: 1.45pt 2.9pt 1.45pt 2.9pt; width: 131.4pt;\" valign=\"top\" width=\"175\">\n<div style=\"page-break-after: avoid; text-align: center;\" align=\"center\"><strong><span style=\"color: white; font-family: 'Arial Narrow'; font-size: 10pt;\">Oklahoma<\/span><\/strong><strong><span style=\"color: white; font-family: 'Arial Narrow'; font-size: 10pt;\"> Pharmacy Law Book<\/span><\/strong><\/div>\n<\/td>\n<td style=\"background: #333399; border-left: none; border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; padding: 1.45pt 2.9pt 1.45pt 2.9pt; width: 2.05in;\" valign=\"top\" width=\"197\">\n<div style=\"page-break-after: avoid; text-align: center;\" align=\"center\"><strong><span style=\"color: white; font-family: 'Arial Narrow'; font-size: 10pt;\">NSF International<br \/>\nDefinition<\/span><\/strong><\/div>\n<\/td>\n<td style=\"background: #3366FF; border-left: none; border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; padding: 1.45pt 2.9pt 1.45pt 2.9pt; width: 167.4pt;\" valign=\"top\" width=\"223\">\n<div style=\"page-break-after: avoid; text-align: center;\" align=\"center\"><strong><span style=\"color: white; font-family: 'Arial Narrow'; font-size: 10pt;\">Sentry Air <\/span><\/strong><\/div>\n<div style=\"page-break-after: avoid; text-align: center;\" align=\"center\"><strong><span style=\"color: white; font-family: 'Arial Narrow'; font-size: 10pt;\">Powder Containment Hoods<\/span><\/strong><\/div>\n<\/td>\n<\/tr>\n<tr style=\"mso-yfti-irow: 1; mso-yfti-lastrow: yes; page-break-inside: avoid;\">\n<td style=\"border-top: none; border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; mso-border-top-alt: solid windowtext .5pt; padding: 1.45pt 2.9pt 1.45pt 2.9pt; width: 131.4pt;\" valign=\"top\" width=\"175\">\n<div><strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">535:15-10-14(5)<\/span><\/strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\"><br \/>\n\u201cWhen asepsis is not required, a Class I BSC, powder containment hood, or isolator intended for containment applications may be sufficient.\u201d<\/span><\/div>\n<\/td>\n<td style=\"border-bottom: solid windowtext 1.0pt; border-left: none; border-right: solid windowtext 1.0pt; border-top: none; mso-border-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-top-alt: solid windowtext .5pt; padding: 1.45pt 2.9pt 1.45pt 2.9pt; width: 2.05in;\" valign=\"top\" width=\"197\">\n<div style=\"line-height: 13.0pt; mso-layout-grid-align: none; mso-line-height-rule: exactly; text-autospace: none;\"><strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">3.4.1 Class I &#8211; <\/span><\/strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u201cA ventilated cabinet for personnel and environmental protection, having an unrecirculated inward airflow away from the operator that exhausts all air to the atmosphere after filtration through a HEPA filter.\u201d <\/span><\/div>\n<div><strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">3.14.1 high efficiency particulate air (HEPA) filter* &#8211; <\/span><\/strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">A throwaway, extended\/ pleated medium, dry-type<\/span><\/div>\n<div><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">filter with the following:<\/span><\/div>\n<div><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u2013 rigid casing enclosing the full depth of the pleats;<\/span><\/div>\n<div><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u2013 minimum particulate removal of 99.99% of particles 0.3 \u03bcm diameter of (Type C)<\/span><\/div>\n<div><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u2013 maximum pressure drop of 1.0 in w.g. (250 Pa) when clean and operated at rated airflow capacity<\/span><\/div>\n<div><\/div>\n<div><strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">*NSF 2008 NSF\/ANSI 49\u00a9 \u00a0<\/span><\/strong><\/div>\n<\/td>\n<td style=\"background: #E6E6E6; border-bottom: solid windowtext 1.0pt; border-left: none; border-right: solid windowtext 1.0pt; border-top: none; mso-border-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-top-alt: solid windowtext .5pt; padding: 1.45pt 2.9pt 1.45pt 2.9pt; width: 167.4pt;\" valign=\"top\" width=\"223\">\n<div><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">The air flow provided by our <a href=\"http:\/\/www.sentryair.com\/dfhapp.htm\">ductless hoods<\/a>, in a range of sizes, meets the Class 1 BSC standard:<\/span><\/div>\n<div style=\"margin-left: .15in;\"><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\"><br \/>\n\u221a inward airflow away from operator<br \/>\n\u221a exhausted through HEPA filtration<\/span><\/div>\n<div><\/div>\n<div><strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">Filtration<\/span><\/strong><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">. Our ductless hoods can be equipped with a variety of filter types, including <a href=\"http:\/\/www.sentryair.com\/hepa-filter.htm\">HEPA<\/a>.<\/span><\/div>\n<div><\/div>\n<div style=\"margin-left: .15in;\"><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u221a Throwaway filters<\/span><\/div>\n<div style=\"margin-left: .15in;\"><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u221a Rigid casing<\/span><\/div>\n<div style=\"margin-left: .15in;\"><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u221a Type C HEPA<\/span><\/div>\n<div style=\"margin-left: .15in;\"><span style=\"font-family: 'Arial Narrow'; font-size: 10pt;\">\u221a Pressure drop <\/span><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div style=\"clear: both; text-align: center;\"><a href=\"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-1438\" title=\"3 - Pharmaceutical Compounding\" src=\"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg\" alt=\"\" width=\"584\" height=\"415\" srcset=\"https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg 1024w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-300x213.jpg 300w, https:\/\/www.sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding.jpg 1936w\" sizes=\"(max-width: 584px) 100vw, 584px\" \/><\/a><\/div>\n<div style=\"clear: both; text-align: center;\"><\/div>\n<div style=\"clear: both; text-align: left;\"><\/div>\n<div style=\"background: white;\">Sentry Air Systems manufactures a broad array of <span style=\"color: blue;\"><a href=\"http:\/\/www.sentryair.com\/pharmaceutical.htm\">ductless powder containment hoods<\/a><\/span> in standard sizes that range from 12\u201d to 70\u201d in width. Customized hoods are also available (e.g., custom size, material, cut-outs, multiple points of entry, increased air volume). For more information about these pharmaceutical containment hoods or any of our air purification products, please call a Sentry Air Systems Applications Specialist at <strong>1.800.799.4609<\/strong>, email us at <a title=\"blocked::mailto:sales@sentryair.com\" href=\"mailto:sales@sentryair.com\"><strong><span style=\"color: #3d85c6; text-decoration: none; text-underline: none;\">sales@sentryair.com<\/span><\/strong><\/a>, or <a title=\"blocked::http:\/\/www.sentryair.com\/feedback-blog.htm\" href=\"http:\/\/www.sentryair.com\/feedback-blog.htm\">fill out this form<\/a>to receive more information or a quote.<\/div>\n<p><P><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This is the second article in a series of three that addresses the Oklahoma Pharmacy Law Book\u2019s airflow and filtration requirements for containment hood systems within compounding pharmacies. The first article in the series discusses the generic qualities of air flow within cabinets and hoods noted in the law book. It also identifies some of&#8230;  <a class=\"excerpt-read-more btn btn-primary\" style=\"display:block; color: #fff;  margin-top: 10px; max-width:120px;\" href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/\" title=\"Read Part Two &#8211; Compounding Pharmacies: Engineering Controls for Non-sterile Compounding\">Learn More<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[805,2448],"tags":[],"class_list":["post-42","post","type-post","status-publish","format-standard","hentry","category-pharmaceutical","category-powder-containment-hood"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Part Two - Compounding Pharmacies: Engineering Controls for Non-sterile Compounding - Sentry Air Systems, Inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Part Two - Compounding Pharmacies: Engineering Controls for Non-sterile Compounding - Sentry Air Systems, Inc.\" \/>\n<meta property=\"og:description\" content=\"This is the second article in a series of three that addresses the Oklahoma Pharmacy Law Book\u2019s airflow and filtration requirements for containment hood systems within compounding pharmacies. The first article in the series discusses the generic qualities of air flow within cabinets and hoods noted in the law book. It also identifies some of... Learn More\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/\" \/>\n<meta property=\"og:site_name\" content=\"Sentry Air Systems, Inc.\" \/>\n<meta property=\"article:published_time\" content=\"2012-03-27T16:04:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2013-05-14T17:52:54+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/\",\"url\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/\",\"name\":\"Part Two - Compounding Pharmacies: Engineering Controls for Non-sterile Compounding - Sentry Air Systems, Inc.\",\"isPartOf\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg\",\"datePublished\":\"2012-03-27T16:04:00+00:00\",\"dateModified\":\"2013-05-14T17:52:54+00:00\",\"author\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/8d78c39e4cd71698fd25d4594e58d21d\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#primaryimage\",\"url\":\"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg\",\"contentUrl\":\"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sentryair.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Part Two &#8211; Compounding Pharmacies: Engineering Controls for Non-sterile Compounding\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#website\",\"url\":\"https:\/\/www.sentryair.com\/blog\/\",\"name\":\"Sentry Air Systems, Inc.\",\"description\":\"Air Purification Systems, Ductless Hoods &amp; Fume Extractors\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/8d78c39e4cd71698fd25d4594e58d21d\",\"name\":\"admin\",\"url\":\"https:\/\/www.sentryair.com\/blog\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Part Two - Compounding Pharmacies: Engineering Controls for Non-sterile Compounding - Sentry Air Systems, Inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/","og_locale":"en_US","og_type":"article","og_title":"Part Two - Compounding Pharmacies: Engineering Controls for Non-sterile Compounding - Sentry Air Systems, Inc.","og_description":"This is the second article in a series of three that addresses the Oklahoma Pharmacy Law Book\u2019s airflow and filtration requirements for containment hood systems within compounding pharmacies. The first article in the series discusses the generic qualities of air flow within cabinets and hoods noted in the law book. It also identifies some of... Learn More","og_url":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/","og_site_name":"Sentry Air Systems, Inc.","article_published_time":"2012-03-27T16:04:00+00:00","article_modified_time":"2013-05-14T17:52:54+00:00","og_image":[{"url":"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/","url":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/","name":"Part Two - Compounding Pharmacies: Engineering Controls for Non-sterile Compounding - Sentry Air Systems, Inc.","isPartOf":{"@id":"https:\/\/www.sentryair.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#primaryimage"},"image":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#primaryimage"},"thumbnailUrl":"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg","datePublished":"2012-03-27T16:04:00+00:00","dateModified":"2013-05-14T17:52:54+00:00","author":{"@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/8d78c39e4cd71698fd25d4594e58d21d"},"breadcrumb":{"@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#primaryimage","url":"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg","contentUrl":"http:\/\/sentryair.com\/blog\/wp-content\/uploads\/2012\/11\/3-Pharmaceutical-Compounding-1024x729.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.sentryair.com\/blog\/industry-applications\/pharmaceutical\/part-two-compounding-pharmacies-engineering-controls-for-non-sterile-compounding\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sentryair.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Part Two &#8211; Compounding Pharmacies: Engineering Controls for Non-sterile Compounding"}]},{"@type":"WebSite","@id":"https:\/\/www.sentryair.com\/blog\/#website","url":"https:\/\/www.sentryair.com\/blog\/","name":"Sentry Air Systems, Inc.","description":"Air Purification Systems, Ductless Hoods &amp; Fume Extractors","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sentryair.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.sentryair.com\/blog\/#\/schema\/person\/8d78c39e4cd71698fd25d4594e58d21d","name":"admin","url":"https:\/\/www.sentryair.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/42"}],"collection":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/comments?post=42"}],"version-history":[{"count":10,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/42\/revisions"}],"predecessor-version":[{"id":1488,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/posts\/42\/revisions\/1488"}],"wp:attachment":[{"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/media?parent=42"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/categories?post=42"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sentryair.com\/blog\/wp-json\/wp\/v2\/tags?post=42"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}