Data Recovery Clean Room

Data Recovery Clean Rooms provide a controlled and reduced particulate enclosure suited for applications such as hard drive restoration, digital forensics, and electronic device repairs. These clean rooms are specifically designed to keep airborne particles such as dust, hair, skin flakes, and microbes from causing significant physical damage to a drive resulting in unrecoverable data. Our data recovery clean rooms meet ISO Class 5 or Class 100 Standards. ISO 14644-1 dictates the maximum number of particles sized 0.5 microns and below for different ISO clean room classifications. ISO Class 5 clean rooms must have the following particle limits per cubic foot to meet certification standards.

ISO Class 5 Clean Room Maximum Number of Particles/ft3

Particle Size
0.1 µm
0.2 µm
0.3 µm
0.5 µm
Maximum # of Particles
100,000
23,700
10,200
3,520

In contrast, an uncontrolled room or space contains about 5 - 10 million airborne particles. ISO Class 5 clean rooms significantly reduce the number of particles per cubic foot through the use of HEPA and ULPA filters. HEPA filters provide efficiency up to 99.97% on particles sized 0.3 microns and larger. ULPA filters create cleaner air with efficiency up to 99.9995% on particles sized 0.12 microns and larger. Clean rooms for data recovery create a proper clean room environment for safe disk drive recovery processes by reducing the airborne particles preventing damage to hard drive components and loss of data.

12"


12
Loading the player...

12in. Portable Clean Room Specifications

    Hood Dimensions:     Hood Material:
     - O.D.: 10.5"D x 12.5" W x 15"H      - Sides: .250" White Acrylic
     - I.D.: 10"D x 12"W x 10"H      - Base: .500" White High Density Polyethylene
     - Top: .500" Clear Polycarbonate
    Front Windows: 0.250" Clear Polycarbonate     Blower Dimensions: 10.5" L x 8" W x 8.5" H
    Total Weight: Approx. 35 lbs.     Motor: Fractional Horsepower

   Available Filter Efficiencies:

   HEPA Filter - Up to 99.97% efficient on particles down to 0.3 microns in size.
   ULPA Filter - Up to 99.9995% efficient on particles down to 0.12 microns in size.

   Electrical:    Sound Level:
    115/1/60, .3 amps     55 dba @ 3 ft. from hood inlet
    220/1/50, .2 amps

   Max Operating Temperature:
   Not to exceed 170 degrees Fahrenheit

   Warranty:
   Limited two-year warranty from date of shipment on defects due to materials or workmanship.

   Patented Design:
   U.S. PATENT #5,843,197

18" ISO Pure


Loading the player...

18in. Portable Clean Room Specifications

    Hood Dimensions:     Hood Material:
     - O.D: 19"D x 20" W x 24"H      - Polyethylene Terephthalate Glycol (PETG)
     - 18"D x 18"W x 15.5"H      - Base: 0.250" Clear Polycarbonate
 
    Blower Dimensions:7.5" L x 7.5" W x 8.5" H     Total Weight: Approx. 11 lbs.
    Motor: Fractional Horsepower

   Available Filter Efficiencies:

   HEPA Filter - Up to 99.97% efficient on particles down to 0.3 microns in size.
   ULPA Filter - Up to 99.9995% efficient on particles down to 0.12 microns in size.

   Electrical:    Sound Level:
    115/1/60, .3 amps     Approx. 55 dba @ 3' from hood inlet
    220/1/50, .2 amps

   Max Operating Temperature:
   Not to exceed 170 degrees Fahrenheit

   Warranty:
   Limited two-year warranty from date of shipment on defects due to materials or workmanship.

   Patented Design:
   U.S. PATENT #5,843,197

18"


18 in Ductless Fume Hood
Loading the player...

18in. Portable Clean Room Specifications

    Hood Dimensions:     Hood Material:
     - O.D.: 18.5"D x 20" W x 19"H      - Sides: .250" White Acrylic
     - I.D.: 18"D x 18"W x 18"H      - Base: .500" White High Density Polyethylene
     - Top: .500" Clear Polycarbonate
    Front Windows: 0.250" Clear Polycarbonate     Blower Dimensions: 10.5" L x 8" W x 8.5" H
    Total Weight: Approx. 35 lbs.     Motor: Fractional Horsepower

   Available Filter Efficiencies:

   HEPA Filter - Up to 99.97% efficient on particles down to 0.3 microns in size.
   ULPA Filter - Up to 99.9995% efficient on particles down to 0.12 microns in size.

   Electrical:    Sound Level:
    115/1/60, .3 amps     55 dba @ 3 ft. from hood inlet
    220/1/50, .2 amps

   Max Operating Temperature:
   Not to exceed 170 degrees Fahrenheit

   Warranty:
   Limited two-year warranty from date of shipment on defects due to materials or workmanship.

   Patented Design:
   U.S. PATENT #5,843,197

24"


Loading the player...

24in. Portable Clean Room Specifications

    Hood Dimensions:     Hood Material:
     - O.D: 24” D x 26” W x 25” H      - Sides: .250" White Acrylic
     - I.D.: 23.5 “D x 24”w x 24” H      - Base: .500" White High Density Polyethylene
     - Top: .500" Clear Polycarbonate
    Front Windows: 0.250" Clear Polycarbonate     Blower Dimensions: 13" L x 13" W x 14.5" H
    Total Weight: Approx. 95 lbs.     Motor: Fractional Horsepower

   Available Filter Efficiencies:

   HEPA Filter - Up to 99.97% efficient on particles down to 0.3 microns in size.
   ULPA Filter - Up to 99.9995% efficient on particles down to 0.12 microns in size.

   Electrical:    Sound Level:
    115/1/60, .3 amps     55 dba @ 3 ft. from hood inlet
    220/1/50, .2 amps

   Max Operating Temperature:
   Not to exceed 170 degrees Fahrenheit

   Warranty:
   Limited two-year warranty from date of shipment on defects due to materials or workmanship.

   Patented Design:
   U.S. PATENT #5,843,197

30"


Loading the player...

30in. Portable Clean Room Specifications

    Hood Dimensions:     Hood Material:
     - O.D: 24"D x 32"W x 25"H      - Sides: .250" White Acrylic
     - I.D.: 23.5"D x 30"W x 24"H      - Base: .500" White High Density Polyethylene
     - Top: .500" Clear Polycarbonate
    Front Windows: 0.250" Clear Polycarbonate     Blower Dimensions:13" L x 13" W x 14.5" H
    Total Weight: Approx. 100 lbs.
    Motor: Fractional Horsepower

   Available Filter Efficiencies:

   HEPA Filter - Up to 99.97% efficient on particles down to 0.3 microns in size.
   ULPA Filter - Up to 99.9995% efficient on particles down to 0.12 microns in size.

   Electrical:    Sound Level:
    115/1/60, 2 amps     Approx. 55 dba @ 3' from hood inlet
    220/1/50, .75 amps

   Max Operating Temperature:
   Not to exceed 170 degrees Fahrenheit

   Warranty:
   Limited two-year warranty from date of shipment on defects due to materials or workmanship.

   Patented Design:
   U.S. PATENT #5,843,197

40"


Loading the player...

40in. Portable Clean Room Specifications

    Hood Dimensions:     Hood Material:
     - O.D: 24"D x 42W" x 25"H      - Sides: .250" White Acrylic
     - I.D.: 23.5"D x 40"W x 24"H      - Base: .500" White High Density Polyethylene
     - Top: .500" Clear Polycarbonate
    Front Windows: 0.250" Clear Polycarbonate     Blower Dimensions:13" L x 13" W x 14.5" H
    Total Weight: Approx. 115 lbs.
    Motor: Fractional Horsepower

   Available Filter Efficiencies:

   HEPA Filter - Up to 99.97% efficient on particles down to 0.3 microns in size.
   ULPA Filter - Up to 99.9995% efficient on particles down to 0.12 microns in size.

   Electrical:    Sound Level:
    115/1/60, 2 amps     Approx. 55 dba @ 3' from hood inlet
    220/1/50, .75 amps

   Max Operating Temperature:
   Not to exceed 170 degrees Fahrenheit

   Warranty:
   Limited two-year warranty from date of shipment on defects due to materials or workmanship.

   Patented Design:
   U.S. PATENT #5,843,197

Hard Drive Recovery Room

A hard drive recovery room must be utilized to safely open a disk drive for inspection and repair. Any dust can physically damage a platter or head on a drive resulting in a higher chance of drive failure and data loss. A platter rotates several thousand times per minute which could stir up a significant amount of dust and particles if opened in an uncontrolled environment. Opening a drive in a hard drive recovery room meets disk drive manufacturer requirements and keeps the warranty valid. Manufacturers create disk drives in a clean room environment and recommend repairing drives in the same ISO Class 5 clean room. A hard drive recovery room enables a trained technician to safely open disk drives, flash drives, and memory cards to recover data. A safe and proper clean room for data recovery increases productivity by allowing the technician to focus on the task and quickly open, inspect and make repairs to damaged hard drives.






  • Data Recovery Clean Room
  • Data Recovery Clean Room
  • Data Recovery Clean Room